No ultrasonic output, Probe, Cables – Dukane DPC II Plus 9001:2000 User Manual
Page 135
125
Dukane Manual Part No. 403–566–01
Section 12 – Troubleshooting
No Ultrasonic Output
Probe
Make sure that the probe coaxial cable is connected
to the generator Ultrasonic output connector J1 (see
Figure 12–1). Make sure the probe stack was as-
sembled following the instructions in Section 10.
Cables
Make sure that both the U/S coaxial and Control
Input cables are connected. You must have a trig-
ger input to the
SYSTEM IN
HD-15 connector ei-
ther by the probe's control cable or custom auto-
mation. Refer to Figures 3–4 through 3–8 for de-
tails. Put the generator OFF LINE and turn off the
AC power switch. Check the coaxial cable for any
signs of damage which may result in an open cir-
cuit preventing the cable from transmitting the sig-
nal from the generator to the probe. If you have a
mounted probe, replace the coaxial cable with a
known good cable. If you are using a hand probe,
try a different known good probe to determine if
the problem is related to the generator or external
cables and probe.
ULTRASOUND
OUTPUT
J1
SYSTEM IN
– WARNING! –
POWER LINE MUST BE
GROUNDED AT OUTLET.
REMOVE ALL POWER BEFORE
REMOVING COVER OR CONNECTING
OR DISCONNECTING CABLES.
DUKANE CORP
ST. CHARLES, IL 60174
MADE IN USA
S E R I A L N U M B E R
U S 1 0 0 0 0
Ultrasound Out
Probe or
Automation
Control Input
Figure 12–1
Rear Ultrasound and System-In Connectors
Ꮨ
CAUTION
Always turn the AC power
off and wait a few seconds,
before disconnecting or con-
necting any cable to the DPC.
Failure to turn off the AC
power may result in damage
to the generator or probe.