II Plus and EZ Welder System – User’s Manual

3. If

DISABLE

was selected in the

AUTO STOP

menu, the

TRIGGER TYPE

menu is displayed

next. This selects whether the trigger which
initiates the weld cycle is momentary or must
be maintained throughout the weld cycle.

4. The

SINGLE PRESSURE

mode follows the

same programming sequence as Weld Method
in the previous Timed Auto Probe. The

DUAL

PRESSURE

mode eliminates ground detect for

obvious reasons and allows welding by Time
or Energy at both pressure level settings.

Initiate Mode

When using a press, the usual choice is to select

MANUAL

for the Initiate Mode. This permits the

dual palm switches to initiate the operate sequence.
If

AUTO

mode is selected, then an external initiate

signal must be supplied to either pins 3 and 4 (Iso
Oper In) or pin 8 (Sw Oper In) of the HD–15 Sys-
tem In connector. Refer back to Figure 5–2 and
Table 5—I for more information.

Auto Stop

The normal configuration when using a press is
to set Auto Stop to

DISABLE

. This permits the stan-

dard emergency OFF switch on the front of the
press base to halt the weld cycle. If Auto Stop is
set to

ENABLE

, then an external signal must be

supplied to pin 9 (Iso Auto Stop) of the HD–15
System In connector. Refer back to the discussion
under Figure 7–13 and also to Table 5—I for more
detailed information.

Head Up On Auto Stop

If

DISABLE

was selected in the

AUTO STOP

menu,

the

HEAD UP ON AUTO STOP

menu is bypassed. If

ENABLE

was selected in

AUTO STOP

, the

HEAD UP

menu is displayed. It offers two choices for head
position. If

ENABLE

is selected for the Head Up op-

tion, the head retracts when an Auto Stop signal is
detected. If the

DISABLE

option is selected, the press

head remains stationary after an Auto Stop signal.
Note that this option and Auto Stop are only avail-
able when the Initiate Mode has been set to Auto.

Trigger Type

If

DISABLE

was selected in the

AUTO STOP

menu,

the

TRIGGER TYPE

menu is displayed next. Other-

wise it follows the

HEAD UP ON AUTO STOP

menu.

If

MOMENTARY

is selected, the trigger switch

is ignored after the first contact closure. The
DPC external bus scan time is 1 msec so the
minimum signal duration is >1 msec. If the
trigger switch opens after the weld cycle is
initiated, the welding processes continues nor-
mally. Momentary is recommended for most
welding processes except hand probes.
If

MAINTAINED

is selected, the trigger must

be maintained during the entire portion of the
weld cycle. If the trigger signal is momentarily
lost while the ultrasonic signal is on, the weld
cycle is terminated. This mode is recom-
mended for special applications. It has an ad-
vantage over momentary trigger in that it will
generate a

TRIGGER LOST

error message if you

suddenly lose trigger force (see Error Messages
in Section 12 – Troubleshooting). This may hap-
pen when welding soft plastic or small parts.

Single/Dual Pressure Mode

The

SINGLE PRESSURE

mode has the same pro-

gramming sequence as Weld method in the pre-
vious Timed Auto Probe. The

DUAL PRESSURE

mode eliminates ground detect and allows Time
or Energy target values to be used at both pres-
sure trigger points. The modes can be mixed us-

NOTE

The word AUTO in the menu options is short
for Automation not automatic. Any menu that
contains the word AUTO means the DPC II Plus
will require an external signal(s) from custom
automation equipment for correct operation.