Preset Part Count

This option allows you to preset a value (maxi-
mum = 60,000) in the counter. Again from the part
count selection menu, move the cursor to the bot-
tom line next to

PRESET PART COUNT

and press

ENTER

. A data entry screen for presetting the value

is displayed. Use the left and right arrow keys to
select the digit position, and the up and down ar-
row keys to increment or decrement the value.

PRESET PART COUNT

_0

The underscore indicates the digit position which
is initially under the right–most digit. To preset the
counter, press

ENTER

and you are returned to the

part count selection menu shown in Figure 9–16.

Status Outputs

The third option in the Utilities Menu (see Figure
9–3) is Status Outputs. Moving the cursor down
to Status Outputs and pressing the

ENTER

key dis-

plays the Status Output Selection menu.

This menu option permits you to set the four Iso-
lated Status Outputs as either maintained or pulsed.
The default setting is maintained. If the output is
set to pulsed, the output pulse width is 100 msec.
The status output selection menu is shown in Fig-
ure 9–20. To change the mode, move the cursor to

PULSED

and press

ENTER

.

STATUS OUTPUTS
MAINTAINED
PULSED

The four outputs controlled by this menu are:
1. Isolated Bad Part on Pin 20
2. Isolated Good Part on Pin 21
3. Isolated Ready on Pin 22
4. Isolated In–Dwell on Pin 23

For a complete description of each signal, refer
back to Table 5—IV.

Cycle Press Off Line

The last option in the Utilities Menu (Figure 9–3)
is Cycle Press Off Line. To access this option move
the cursor down to the last line and press

ENTER

.

This subsequent menu is shown in Figure 9–21.

CYCLE PRESS OFF LINE
YES
NO

This option works only with the palm operate
switches on the press base. When the DPC front
panel status is set

OFF LINE

, it cannot be triggered

to cycle the press. During testing or fixture setup,
it may be necessary to cycle the press without pro-
ducing an ultrasonic output signal. This menu op-
tion permits cycling the press with the DPC set to

OFF LINE.

To enable this menu option, move the

cursor key up one line to

YES

and press the

ENTER

key. The press can now be cycled by pressing both
palm activation switches. without producing an ul-
trasonic output signal. An Automation Input signal
(pin 8 of J902) will not cycle the press with this
menu option with the DPC set to

OFF LINE

.