beautypg.com

Current source control circuit, High side switch sources current – Dukane DPC II Plus 9001:2000 User Manual

Page 176

background image

166

Dukane Manual Part No. 403–566–01

DPC

II Plus and EZ Welder System – User’s Manual

DPC II Plus
+22V Power

High-Side

Switch

Sources

Current

DPC Ground

+22V

DPC Internal
Power Supply

Current
Limit Circuit
250mA max.

Jumper Block SH707
Position JU725

(Refer to Figure 5–12)

+24V

Internal
DPC II Plus
Circuitry

Optical Isolation

Circuit

Current
Limit Circuit
12.5 mA

max.

12.5 mA

max

4 mA

min

Isolated Input

Pin #3 – Operate
Pin #5 – Press Control
Pin #9 – Auto Stop

Pin #1

User
Supplied
Switch
Circuitry

Pin #2 & Pin #7

No Connection

Current Source Control Circuit

Figure C–4 illustrates an automation control cir-
cuit connected to the highside of one of the Iso-
lated Automation Inputs. Even though the switch
drives an Opto–Isolator, it is still connected to
the DPC power source and not isolated. The
SH707 jumper block must be in the JU725 posi-
tion (see Figure 5–12). Any of the examples in
Figure C–2 can be used in place of the block la-
beled

High Side Switch Sources Current.

Figure C–4

Current Source Switch