beautypg.com

Dimensions, Operating environment, Storage guidelines – Dukane DPC II Plus 9001:2000 User Manual

Page 158: Ii plus and ez welder system – user’s manual, Figure 15–1 generator 3–view and dimensions

background image

148

Dukane Manual Part No. 403–566–01

DPC

II Plus and EZ Welder System – User’s Manual

Dimensions

Operating Environment

Operate the DPC II Plus within these guidelines:
Temperature:

40

°

F to 100

°

F (+5

°

C to +38

°

C)

Pressure:

Ambient

Air Particulates:

Keep the DPC dry.
Minimize exposure to moisture,
dust, dirt,smoke and mold.

Humidity:

5% to 95% Non–condensing
@ 0

°

C to +30

°

C

Vibration:

1.0 G

Storage guidelines:

Temperature:

-4

°

F to 158

°

F (-20

°

C to +70

°

C)

Humidity:

5% to 95% Non–condensing
@ 0

°

C to +30

°

C

Vibration:

2.5 G

23.78 in

604 mm

Cooling
Air Inlet

Cooling Fan

Allow 4 in (10 cm)

space for cables

Allow 2 in (5 cm)

space for ventilation

Heated

Exhaust Air

Allow 2 in (5 cm)

space for ventilation

Allow 4 in (10 cm)

space for cables

17.17 in
436 mm

5.12 in

130 mm

5.47 in

139 mm

ƽ

DUKANE CORP
ST. CHARLES, IL 60174
MADE IN USA

S E R I A L N U M B E R

U S 1 0 0 0 0

– WARNING! –

POWERLINE MUST BE GROUNDED

AT OUTLET

REMOVE ALL POWER BEFORE

REMOVING COVER OR CONNECTING

OR DISCONNECTING CABLES.

ULTRASOUND

OUTPUT

SYSTEM OUT

+

Power Monitor

Jacks

Power Signal

Output Module

Power
Signal
Output

Zero

Adjust

SYSTEM IN

J1

U. S . PAT E N T 4 , 2 7 7 , 7 1 0

– WARNING–

POWER LINE MUST BE

GROUNDED AT OUTLET

LINE VOLTAGE

200–240Vac 50/60Hz

15A

M O D E L N U M B E R

2 0 0 - 2 4 0 VAC, 5 0 - 6 0 H z , 1 5 A

Multi–Probe Slave Module

Multi–Probe Master Module

Press Control Board

Power Signal Output

Figure 15–1 Generator 3–View and Dimensions