Press mode, Trigger method – press, Initiate mode – Dukane DPC II Plus 9001:2000 User Manual
Page 85: Auto stop, Head up on auto stop, Head up, Trigger method, Menu is also expanded and offers a choice of, Mode has an, Menu preceding auto stop. the
75
Dukane Manual Part No. 403–566–01
Section 7 – Process Control Menu
PRESS Mode
The cable connection diagram for connecting a
DPC II Plus to a Dukane press is shown in Sec-
tion 3 in Figures 3–8. The flow chart for the Pro-
cess Control menu is shown in Figure 7–30. If a
Press Control module is not installed, this menu
will not be displayed. If you do not have a Power
Output module installed, the Energy Weld Method
menu options will not appear either.
The Press Setup logic features two areas of enhance-
ment over the Auto Probe logic. The
PRESS TRIG-
GER METHOD
has three additional control options
in the Auto Stop logical branch (the Auto Probe
trigger methods are still available). The
WELD
MODE
menu is also expanded and offers a choice
of
SINGLE PRESSURE
or
DUAL PRESSURE
mode.
Compare the flowchart in Figure 7–30 to the previ-
ous Auto Probe flowchart in Figure 7–21.
1. The
TRIGGER METHOD – PRESS
mode has an
INITIATE MODE
menu preceding Auto Stop.
The
MANUAL
mode is the recommended set-
ting. This permits the dual palm switches on
the press base to initiate the operate sequence.
2. If
ENABLE
was selected in the
AUTO STOP
menu, the
HEAD UP ON AUTO STOP
menu is
displayed. Auto Stop has been covered previ-
ously under MPC Probe and AUTO Probe. The
HEAD UP
menu determines whether the press
head remains at its last position or retracts when
an external Auto Stop signal is detected.
PRESS
MANUAL
INITIATE
MODE
AUTO
MOMENTARY MAINTAINED
TRIGGER TYPE
WELD
MODE
1
1
2
2
HOLD
TIME
PROCESS CONTROL
AFTER–
BURST
Step 1
Timed
Auto
Probe
Bypasses
Single/Dual
Pressure
Mode
DPC II Plus
Models
Only —
Not Avail-
able on
EZ Series
Press Trigger
Method Only
Step 2
Step 3
RTW
AUTO STOP
ENABLE DISABLE
HEAD UP ON
AUTO STOP
WELD MODE
DUAL
PRESSURE
SINGLE
PRESSURE
WELD METHOD
TIME ENERGY
GND.
DETECT
PRESSURE 1
TIME
ENERGY
PRESSURE 2
TIME
ENERGY
ENABLE DISABLE
UNTIMED AUTO PROBE
TRIGGER METHOD
TIMED AUTO PROBE
ENABLE or DISABLE
AUTO STOP
RTW
E/D
ENTER
Enable/
Disable
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
T
hold
T
we
ld
T
1
we
ld
E
we
ld
E
1
we
ld
E
2
we
ld
T
max
T
1
max
T
2
max
T
max
T
scrub
T
2
we
ld
T
dela
y
T
bu
rs
t
T
dela
y
SINGLE
PRESSURE
PRESS
DUAL
PRESSURE
PRESS
Figure 7–30
Press/Auto Probe Setup Flow Chart
NOTE
The symbol legend for the Press Mode flow chart
is the same as the other flow charts. It is re-
peated here for your convenience.
T
we
ld
RTW = Ready To Weld
LEGEND
= Front Panel ENTER Key
(Section 4.3 – Menu Keys)
ENTER
= Parameter Value Entry
T = Time
E = Energy