beautypg.com

Press mode, Trigger method – press, Initiate mode – Dukane DPC II Plus 9001:2000 User Manual

Page 85: Auto stop, Head up on auto stop, Head up, Trigger method, Menu is also expanded and offers a choice of, Mode has an, Menu preceding auto stop. the

background image

75

Dukane Manual Part No. 403–566–01

Section 7 – Process Control Menu

PRESS Mode

The cable connection diagram for connecting a
DPC II Plus to a Dukane press is shown in Sec-
tion 3 in Figures 3–8. The flow chart for the Pro-
cess Control menu is shown in Figure 7–30. If a
Press Control module is not installed, this menu
will not be displayed. If you do not have a Power
Output module installed, the Energy Weld Method
menu options will not appear either.

The Press Setup logic features two areas of enhance-
ment over the Auto Probe logic. The

PRESS TRIG-

GER METHOD

has three additional control options

in the Auto Stop logical branch (the Auto Probe
trigger methods are still available). The

WELD

MODE

menu is also expanded and offers a choice

of

SINGLE PRESSURE

or

DUAL PRESSURE

mode.

Compare the flowchart in Figure 7–30 to the previ-
ous Auto Probe flowchart in Figure 7–21.

1. The

TRIGGER METHOD – PRESS

mode has an

INITIATE MODE

menu preceding Auto Stop.

The

MANUAL

mode is the recommended set-

ting. This permits the dual palm switches on
the press base to initiate the operate sequence.

2. If

ENABLE

was selected in the

AUTO STOP

menu, the

HEAD UP ON AUTO STOP

menu is

displayed. Auto Stop has been covered previ-
ously under MPC Probe and AUTO Probe. The

HEAD UP

menu determines whether the press

head remains at its last position or retracts when
an external Auto Stop signal is detected.

PRESS

MANUAL

INITIATE

MODE

AUTO

MOMENTARY MAINTAINED

TRIGGER TYPE

WELD

MODE

1

1

2

2

HOLD

TIME

PROCESS CONTROL

AFTER–

BURST

Step 1

Timed

Auto

Probe

Bypasses

Single/Dual

Pressure

Mode

DPC II Plus

Models

Only —

Not Avail-

able on

EZ Series

Press Trigger

Method Only

Step 2

Step 3

RTW

AUTO STOP

ENABLE DISABLE

HEAD UP ON

AUTO STOP

WELD MODE

DUAL

PRESSURE

SINGLE

PRESSURE

WELD METHOD

TIME ENERGY

GND.

DETECT

PRESSURE 1

TIME

ENERGY

PRESSURE 2

TIME

ENERGY

ENABLE DISABLE

UNTIMED AUTO PROBE

TRIGGER METHOD

TIMED AUTO PROBE

ENABLE or DISABLE

AUTO STOP

RTW

E/D

ENTER

Enable/

Disable

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

T

hold

T

we

ld

T

1

we

ld

E

we

ld

E

1

we

ld

E

2

we

ld

T

max

T

1

max

T

2

max

T

max

T

scrub

T

2

we

ld

T

dela

y

T

bu

rs

t

T

dela

y

SINGLE
PRESSURE
PRESS

DUAL
PRESSURE
PRESS

Figure 7–30

Press/Auto Probe Setup Flow Chart

NOTE

The symbol legend for the Press Mode flow chart
is the same as the other flow charts. It is re-
peated here for your convenience.

T

we

ld

RTW = Ready To Weld

LEGEND

= Front Panel ENTER Key
(Section 4.3 – Menu Keys)

ENTER

= Parameter Value Entry
T
= Time
E
= Energy