Erase all setups no yes, Erasing all setups in process, Reset part count no yes – Dukane DPC II Plus 9001:2000 User Manual

Page 110: Count sus/bad part no yes, Part count

background image

100

Dukane Manual Part No. 403–566–01

DPC

II Plus and EZ Welder System – User’s Manual

To erase all the stored setups, move the cursor from

ERASE CURRENT SETUP

(see Figure 9–11) to

down to

ERASE ALL SETUPS

and press

ENTER

. A

confirmation message is displayed. Move the cur-
sor down to

YES

as shown in Figure 9–14. Press

the

ENTER

key to delete the setup files.

ERASE ALL SETUPS
NO
YES

A progress message (see Figure 9–15) appears for
about 8 seconds. When the process is complete,
the display returns to the Process Setup menu as
shown in Figure 9–2

ERASING ALL SETUPS
IN PROCESS...

.

Part Count

The parts count option (see Figure 9–3) offers three
options. The three choices are to reset the counter,
count suspect/bad parts and preset the counter as
shown in Figure 9–16.

PART COUNT
RESET PART COUNT
COUNT SUS/BAD PART
PRESET PART COUNT

The count replaces the - - - in the upper left of the
operate screen (see Figures 7–3. 7–4, 7–31 and 7–53).

Reset Part Count

This function resets the parts counter back to zero.
With the cursor at the reset function, press the

ENTER

key. The confirmation screen shown in

Figure 9–17 is displayed next.

RESET PART COUNT
NO
YES

Use the decrement key to move the cursor down
one line to

YES

and press the

ENTER

key. The

counter will be reset and the menu returns to the
part count selection menu shown in Figure 9–16.

Count Suspect/Bad Part

The second option controls the suspect/bad part
counter. The counter can be set to count all parts or
only the good parts. To configure the counter, move
the cursor down to

COUNT SUS/BAD PART

(see

Figure 9–16) and press

ENTER

. A confirmation

screen (shown in Figure 9–18) is then displayed.

COUNT SUS/BAD PART
NO
YES

To count all parts, move the cursor to

YES,

press

ENTER

and the menu returns to the part count se-

lection screen shown in Figure 9–16. To exclude
bad/suspect parts, move the cursor to

NO

and press

ENTER.

The bad/suspect parts are ignored and only

good parts are counted. The menu returns to the
part count selection screen shown in Figure 9–16.

Figure 9–14

Confirm Erase All Setups

Figure 9–15

Erasing All Setups In Process

Figure 9–16

Part Count Selection Menu

Figure 9–18

Confirm Counter Enabled

Figure 9–17

Confirm Reset Part Count