beautypg.com

Generator status panel, Generator control keys – Dukane DPC II Plus 9001:2000 User Manual

Page 40

background image

30

Dukane Manual Part No. 403–566–01

DPC

II Plus and EZ Welder System – User’s Manual

1. AC Power Section

The front-panel AC power section has a switch and
power indicator that is shown in Figure 4-2.

ON/OFF

The AC power switch connects AC
power to the generator. This breaker
switch is wired in series with the rear
panel power switch (Figure 3–9). It also
serves as a circuit breaker that provides
overload protection for the DPC. Both
switches must be turned on to supply
AC power to the generator.

Green LED

The green indicator above the switch
lights when the DC bus is up, after the
AC power has been switched on. At
this point the generator is capable of
producing an ultrasonic output signal.

2. Generator Status Panel

The Generator Status Panel is subdivided into three
sections which provide control and status displays.

1. Generator Control Keys

2. System Status Display

3. System Power Output Display

Generator Control Keys

The Generator Control Key section consists of three
keys as shown in Figure 4-3.

ON LINE

This places the generator in an opera-
tional state. It can produce an ultra-
sonic output signal when triggered.

TEST

The

TEST

key momentary activates the

generator to provide ultrasound out-
put for test or setup purposes.

TEST

will only work in the

ON LINE

state.

OFF LINE

This key places the generator in a
standby mode. This prevents the gen-
erator from producing an ultrasonic
output signal.

Green
Power
Indicator

Front
AC Power
Switch

ON LINE
Key

TEST
Key

OFF LINE
Key

Figure 4–3 Generator Control Keys

Figure 4–2 Front Panel AC Power Section

NOTE

If a Press module is installed, these keys are
only active if the Emergency Stop is not
engaged. If the Emergency Stop switch is
depressed, the System Status Display will
not be lit and the Control Keys inactive.