Dukane Manual Part No. 403–566–01

Section 3 – Unpacking and Installation

ƽ

DUKANE CORP
ST. CHARLES, IL 60174
MADE IN USA

S E R I A L N U M B E R

U S 1 0 0 0 0

– WARNING! –

POWERLINE MUST BE GROUNDED

AT OUTLET

REMOVE ALL POWER BEFORE

REMOVING COVER OR CONNECTING

OR DISCONNECTING CABLES.

ULTRASOUND

OUTPUT

SYSTEM OUT

+

Power Monitor

Jacks

Power Signal

Output Module

Power
Signal
Output

Zero

Adjust

SYSTEM IN

J1

U. S . PAT E N T 4 , 2 7 7 , 7 1 0

– WARNING–

POWER LINE MUST BE

GROUNDED AT OUTLET

LINE VOLTAGE

200–240Vac 50/60Hz

15A

M O D E L N U M B E R

2 0 0 - 2 4 0 VAC, 5 0 - 6 0 H z , 1 5 A

Earth Ground

#14 Gauge
Wire

110 VAC or
220 VAC

Grounding Lug

Grounding Lug

Ultrasound

Input

Automation
Control

Status
Output
P/N 200–1302

Coaxial Cable

RG62B/U

#14 Gauge Wire

Automation

Equipment

P/N 200–1203

P/N 200–479

ƽ

DUKANE CORP
ST. CHARLES, IL 60174
MADE IN USA

S E R I A L N U M B E R

U S 1 0 0 0 0

– WARNING! –

POWERLINE MUST BE GROUNDED

AT OUTLET

REMOVE ALL POWER BEFORE

REMOVING COVER OR CONNECTING

OR DISCONNECTING CABLES.

ULTRASOUND

OUTPUT

SYSTEM OUT

+

Power Monitor

Jacks

Power Signal

Output Module

Power
Signal
Output

Zero

Adjust

SYSTEM IN

J1

U. S . PAT E N T 4 , 2 7 7 , 7 1 0

– WARNING–

POWER LINE MUST BE

GROUNDED AT OUTLET

LINE VOLTAGE

200–240Vac 50/60Hz

15A

M O D E L N U M B E R

2 0 0 - 2 4 0 VAC, 5 0 - 6 0 H z , 1 5 A

J901 T

O

THR

USTER

J902 B

ASE/

ABOR

T

Jumper Block
Part No. 200–1293

Pins 3 & 9
Connected

1

5

3

6

9

Earth Ground

#14 Gauge
Wire

Flexible + Coaxial Cable
20kHz Part No. 200–624
40kHz Part No. 200–759
(Included with probe)

Grounding Lug

110 VAC or
220 VAC

14–Pin AMP to

HD–15 Adapter

Part No. 200–1248

The 3–prong AC Line cords supplied are
matched to the DPC II Plus power rating and
the continent of specified use.
The part numbers are —
200–1109

North America 110V

200–1110

North America 220V

200–1111

Continental Europe

Figure 3-4 DPC II Plus and EZ Welder Hand Probe Cable Connections

Figure 3-5 DPC II Plus and EZ Welder Automated Probe Cable Connections

Table 3—

II

DPC II Plus AC Power Cord Part Numbers

Step 4.

Optional – Attach the status output
cable from the user–supplied
automation equipment to the System
Output DB-25 connector. Not all
automation systems will have this cable.

Step 5.

Attach the power cord to the DPC II
Plus and plug the other end into an
approved AC outlet.