beautypg.com

Dukane DPC II Plus 9001:2000 User Manual

Page 77

background image

67

Dukane Manual Part No. 403–566–01

Section 7 – Process Control Menu

is reached, whichever comes first. Press

ENTER

and

the data entry screen appears as shown in Figure
7–9. If a Power Output module is installed, then a
Weld Method screen shown in Figure 7–8 is dis-
played first. Press the

ENTER

key to display the weld

time data entry. If a Power Output module is not
installed, there is only one choice and the Weld
Method screen is bypassed. Timed Hand Probe op-
eration requires the weld time to be entered. Use the
Left and Right arrow keys to move to the desired
digit position and the Up and Down arrow keys to
increment or decrement the value. When the desired
value is displayed, press

ENTER

for the next menu

until all the required values have been entered.

Timed Hand Probe – Energy

If a Power Output module is installed, you can also
choose the Weld By Energy method. From the
Weld Method screen shown in Figure 7–8, move
the cursor down so it points to Weld By Energy
and press the

ENTER

key.

To weld using the Energy Method, you first enter
the desired welding energy, This data entry screen
is shown in Figure 7–10. Enter the desired weld-
ing energy and press

ENTER .

Now enter the maxi-

mum weld time as shown in Figures 7–11. Press

ENTER

to complete the process. You will return to

the Process Setup menu (Figure 7–5).

WELD METHOD
WELD BY TIME
WELD BY ENERGY

WELD ENERGY

75 J

MAX WELD TIME

1.000 SEC

WELD TIME

0.500 SEC

Figure 7–9

Hand Probe Weld Time

Figure 7–10

Hand Probe Weld Energy

Figure 7–11

Hand Probe Max Weld Time

Figure 7–8

Hand Probe Weld Method

NOTE

The flowchart beginning with powerup to the
Process Setup menu (Figure 7–5) and the Trigger
Method screen (Figure 7–6) is shown in Figure
6–5. A portion of the drawing is repeated here.

Only present if
Power Output Module
is installed

TRIGGER METHOD
TIMED PROBE
UNTIMED PROBE

PROCESS SETUP
PROCESS CONTROL
PROCESS LIMITS
UTILITIES

----- #1 TIME ENERGY

0.000 0

MODE

MODE

MODE

CANCEL

CANCEL

ENTER

Figure 7–3 and 7–4

Figure 7–5

Figure 7–6