Troubleshooting

Electronics Problem

No display when ÜN/OFF button
pushed

Display shows: ele

Display dim

Display dark

Possible Cause(s)

Battery incorrectly installed

Battery contacts dirty

Dead battery

Display failure

Normal at battery installation

Reference points not set

Poor battery contact

Display failure

Low battery voltage

Saw very cold

Saw very warm

Display blanks after a few minutes Normal

Display blanks when moving car­
riage, then re-appears when mo­
tion stops

Normal when position is changed
rapidly

Display shows: EEE.E or EE.EE

Arm or carriage moved abruptly

or too rapidly when display is off

Display resets but immediately
shows EEE.E or EE.EE when
carriage is moved

Display does not change when
arm or carriage is moved

Display does not read 0“ or
45° at bevel or miter indexes

Defective encoder or display in­
dicator

Wrong function selected

Defective encoder or display in­

dicator

"O" reference points not set at in­

dexed points

Miter and bevel encoders not

aligned

What to Do

Install battery correctly

Clean battery contacts

Replace with 6V, size J battery

Have electronics checked by Scars

No action

Set "0" reference points

Clean battery contacts

Have electronics checked by Sears

Replace with 6V, size J battery

Allow saw to warm above 32°F

Allow saw to cool below 120°F

Push ON/OFF to see display

No action

Re-set ”0" reference point(s)

Have electronics checked by Sears

Select correct function

Have electronics checked by Sears

Set "0" reference points

Align encoders