Potter PFC-6075R User Manual
Page 8
1-2
PFC-6075R • 5403594 • REV D • 9/14
y
y
99 Software Zones
y
y
Dead-front Cabinet Design
y
y
2 X 16 character LCD display
y
y
Dedicated Alarm, Supervisory and Trouble Form C Relays
y
y
Analog / Addressable Sensing Technology
y
Drift Compensation
y
Drift Alert
y
NFPA 72 compliant calibrated smoke test built-in
P-Link Accessories
y
y
RA-6500R, RA-6500 or RA-6075R, RA-6075 Remote Annunciator – Maximum of 31 per system in any combination
y
y
UD-1000 Dual Line Fire Communicator – Maximum of 1 per system
y
y
CA-6075 Class A converter module – Maximum of 1 per system allows for Class A wiring of the SLC circuit, P-Link
communication bus and the two (2) built-in NAC circuits
y
y
PSN-1000 / PSN-1000(E) Intelligent Power Supply Expander – An accessory to the panel providing ten (10) amps of
additional power, with four (4) input points, six (6) notification circuits, and a P-Link interface
y
y
LED-16 Annunciator module - Maximum of 10 total per system (the total may be any combination of LED-16 and
DRV-50 LED modules) allows for up to 16 zones alarm, supervisory and trouble conditions to display, and 5 non-
programmable system LEDs that display system's overall condition
y
y
DRV-50 LED Driver module - Maximum of 10 total per system (the total may be any combination of LED-16 and DRV-50
LED modules) allows output to up to 50 LEDs, 4 dry contact inputs, and 5 non-programmable system LEDs that display
system's overall condition
y
y
RLY-5 Relay Board module - Maximum of 31 per system provides five (5) Form-C relay outputs
y
y
FCB-1000 Fire Communications Bridge module - An accessory that provides a remotely-located IP connection to the panel
y
y
FIB-1000 Fiber Interface Bridge - An accessory to the panel that converts the standard 4-wire P-Link bus to and from optic
cable capable of Class A operation; maximum of 30 total per system
y
y
SPG-1000 Serial Parallel Gateway - An accessory to the panel that provides a serial or parallel printer connection;
maximum of 31 per system
SLC Loop Accessories
• Addressable Sensors
y
Photoelectric Smoke Detector (PSA)
y
Photoelectric/Heat Smoke Detector (PSHA)
y
Fixed Temperature Heat Detector (FHA)
y
Rate of Rise/Fixed Temperature Heat Detector (RHA)
y
Addressable Isolator Base (AIB)
y
Addressable Relay Base (ARB)
y
Addressable Sounder Base (ASB)
y
Addressable Pull Station (APS)
• Addressable Modules
y
Miniature Contact Module (MCM)
y
Single Contact Module (SCM-4)
y
Dual Contact Module (DCM-4)
y
Twin Relay Module (TRM-4)
y
Monitored Output Module (MOM-4)
y
Conventional Input Zone Module (CIZM-4)
y
Short Circuit Isolator (SCI)