8,2*15 Fixed-Value Output

The fixcd-v^ilue output is used to output y fixed current and

u

fixed pulse output indepcndenl

of the flow rate signal, (The fixed pulse output is available only when DOl is used for

PUUSE: OUT function.) The fixed-value output can be set in the ranges described below^

(Current output and pulse output can be set and output at the same time.)

Fixed

ciMTent output: 3 to 24 mA

(in

increments of 0.1 mA)

• Fixed pulse output:

0

to 1(1 GO pps (in increments of 1 pps)

If you have disabled this function (set to OFF), you do not have to set the subsequent

current and pulse output values.

When this function is enabled (set to ON), I he measured data is displayed with the primary

indicating unit only on the first line of the display and the fixed current output is displayed

on the second line otThe display. Other data output and display conditions are as follows;

• Current output:

User-set current output

• pulse output:

Pulse ou-put with a user-set counting rate

• Digital output(s): Previous status is retained (excluding pulse output).

• Data Display:

Instantaneous flow rates and flow velocity (no totalization)

Display example;

1.000 n/s -

^ riX* OUT ¿0* 0 itiA

'Primary indicating unit

Fixed current output value

display

This fixed-value output function does not work in the calibration mode.

Proceed as follows to check or change the enable/disable status of the fixed-value output

and its output values.

-