beautypg.com

To change the meter ssize, Important, Toshiba – Toshiba LF494 User Manual

Page 49

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

TOSHIBA

6 F 8 A 0 7 7 4 ,

To change the meter ssize:

IMPORTANT

Meter sii^e iii 1 actory set when shipped. Do not change the meter size unless it differs
from the specified value.

The following example shows how lo change The meter size from 5f) mm to 100 mm.

Key operation

Display example

Description

SET

A2; METER SIZE

50 nur

Press [SET| first to start the uems selection

sequence and select A2: METERSIZE from among
the configuration items using [ ► ]and[A]keys.

Press [SET] again to display the current meter size

fSO mm ill this e.xample).

M :

METER SIZE

50 nut

Pressing [ ► ], the cursor apijcars.

AZ: METER SIZE

100

inin

Select "‘100 mm” by pressing [

a

] as many times

as necessary. (Note)

SET

K Z \

METER SIZE

100

mm

Pressing [SET], the cursor disappears and the changed

display flickers. Press [SET] again to save the value.

SET

n

AZ: METER SIZE

Pressing [SET], the system relurns to the items

selection sequence.

c:

Note: The meter size is changed as shown below by pressing [

a

],

2.5 mm 15 mm “► 100 iiiin

f^iXl mm —►0.1 in 0,5 in^4 in • 24 in

Tf the meter size has been changed, other setting values (such as span and counting rate)

will be affected depending on the measuring unit u.sed. therefore, check those setting

values if you have changed the meter size,

-

43

This manual is related to the following products: