C2) PipÊ Orientation
The detector may be installed in horizontal, vertical or sloping pipe runs as shown in
Figure 4,3, However, cxccpl for horizontal installation, llmd should flow from lower to
upper directions. See Figure 4.3.
r ~
I
I^Cb)
Fldw direction
(a) Horizontal pipe instailation
(h) Vertical pipe installation
(c) Sloping pipe insialiation
Ground sgriace
Figure
43
Detector Piping Orientation
The electrodes should be positioned horizontally against the ground surface in any piping
installation. See Figure 4.4.
(Jmss-scdiiin A - A
Ground surface
Figure 4.4 Installation position of the detector
-