To change the hysteresis:
The hysteresis is seL ai 3% (deiauJl) when shipped from the factory.
The foil owing example shows how to change the hysteresis from
3 % t o 5 % .
Key operation
Display example
Description
SCT
□
C6; RANGE HYST
03. 0
%
Press [SHTj first to start ihe items selection sequence
and selccl C
6
: RANGE HYiil from among the
configuration items using [ ► ] and [
a
] keys. Then
press [SET] again to display the current hysteresis
(3.0% in this exampleV
►
□
C6: RANGE HYST
03.0
%
Pressing [ ► |, the cursor appears*
►
□
C6: RANGE HYST
03-0
%
Press [ ► j to move the cursor to the desired digit to
change.
▲
□
C6: RANGE HYST
05.0
%
Change the value to “5" by pressing [ ^ J twice,
(if necessary, move the cursor to another digit and
change the value).(Note)
S E T
□
C6. RANGE HYST
05.0
%
Pressing [SET]» the cursor disappears and the
changed display flickers. Press [SET] again to store
the changed hysteresis.
SLT
□
C6; RANGE HYST
Pressing [SET], the system returns to the item selec-
lion sequence.
Note: If you try to set the hysteresis !itx)ve 25.0 an error messageH, OVER SPEC.’
appears. Try again to set the value within the specified range.