Low cu(off, Toshiba – Toshiba LF494 User Manual
Page 66
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
TOSHIBA
6 F 8 A 0 7 7 4
Low Cu(off
The low culoff is Lhc value sei jusl above
0 %
flow' rate. Flow' rates below' this level are
treated as and subsequent outputs as
0 %
current outptit. I'hc low cutoff can be set from
0
to
10
% of the span and in incrementii of
0.1
%,
Proceed as follow's to check or change the low' cutoff value,
■ To check the low cutoff value:
K.e> operation
Display example
Description
SRT
□
Press [SliT] first to start the items selection sequence
[)2: LO* CUT
to select D2: LOW CUT from among the configuration
Ok
0
%
items using [ ► ] and [ A ] keys. Press [SETj again to
display the current low cutoff value.
Stir
U 2 :
LOi CLT
Pressing [SET], the system returns to the items
□
selection sequence.
-
65
-