Wiring the breakout board – Dynojet 250iPX: Installation Guide User Manual
Page 65
I N S T A L L A T I O N
Routing Cables
Version 2
In Ground Model 200iPX/250iPX Motorcycle Dynamometer Installation Guide
2-43
W
IRING
THE
B
REAKOUT
B
OARD
1
Attach the temperature sensor cable to the Breakout board. The temperature
sensor cable has five wires which connect to the wiring block labeled TEMP. This
cable was routed to the Breakout board on page 2-39.
2
Attach the theta controller cable to the Breakout board, if it is not already
connected. The theta controller cable has five wires which connect to the wiring
block labeled LOAD CONTROL.
3
Attach the pickup; card cable to the Breakout board. The pickup card cable has
four wires which connect to the wiring block labeled DRUM 1.
4
Verify jumpers J1 and J2 are set either for the eddy current brake and air brake or
for the air brake only as shown in Figure 2-35.
If you have an eddy current brake and air brake, the air brake will only be
activated when the dyno electronics power is turned off, the E-stop button is
pressed, or the optional door interlock is installed and activated.
• Green wire connects to G1
• White wire connects to W1
• Black wire connects to B1
• Red wire connects to R1
• Ground (shield) wire connects to S1
• Black wire connects to V-
• Red wire connects to V+
• White wire connects to O+
• Green wire connects to O-
• Ground (shield) wire connects to SH
• Red wire connects to R1
• Black wire connects to B1
• White wire connects to W1
• Ground (shield) wire connects to S1