In Ground Model 200iPX/250iPX Motorcycle Dynamometer Installation Guide
C H A P T E R 4
Power Distribution Assembly
4-8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
POWER DISTRIBUTION ASSEMBLY
The Power Distribution Assembly, inside the CPI, has three circuit breakers to protect
the internal dyno circuits, the main dyno circuit breaker and two blower circuit
breakers.
M
AIN
C
IRCUIT
B
REAKER
The main circuit breaker is rated for 240VAC at 30A and all of the power into the dyno
passes through this breaker. In the event of a major overload or failure this breaker
will trip. This breaker also provides the main disconnect for the dyno. When the
handle is in the up position the dyno is connected to the incoming power. When the
handle is in the down position all power into the dyno is turned off.
Even if this breaker is turned off there is still the potential for lethal voltages to
be present in the CPI. Always disconnect the main power plug before removing
the covers.
H
IGH
P
RESSURE
B
LOWER
C
IRCUIT
B
REAKERS
The high pressure blower (blower) circuits are protected by the two 15A breakers. In
the event of a motor failure or other failure with the blowers these breakers could
trip. The white button pops out to indicate the circuit has tripped. Pressing in the
white button will reset the breaker. The top breaker protects the right blower circuit
(right side of dyno as you are sitting on the bike) and the bottom breaker protects the
left blower circuit. These breakers do not provide a manual disconnect.
Figure 4-2: CPI Circuit Breakers
PD047
main dyno circuit
breaker and disconnect
blower circuit breakers
right blower on top