Configuring virtual lan tag properties for cmc – Dell POWEREDGE M1000E User Manual
Page 80

IP filtering compares the IP address of an incoming login to the IP address range that is specified. A login from the
incoming IP address is allowed only if both the following are identical:
•
cfgRacTuneIpRangeMask bit-wise and with incoming IP address
•
cfgRacTuneIpRangeMask bit-wise and with cfgRacTuneIpRangeAddr
NOTE:
•
To enable the IP range checking feature, use the following property under cfgRacTuning group:
cfgRacTuneIpRangeEnable <0/1>
•
To specify the range of IP addresses that you want to block from accessing CMC, use the following property under
cfgRacTuning group:
cfgRacTuneIpRangeAddr
•
To specify the IP Range Mask that you want to block from accessing CMC, use the following property under
cfgRacTuning group:
cfgRacTuneIpRangeMask
Configuring Virtual LAN Tag Properties for CMC
VLANs are used to allow multiple virtual LANs to co-exist on the same physical network cable and to segregate the
network traffic for security or load management purposes. When you enable the VLAN functionality, each network
packet is assigned a VLAN tag.
Configuring Virtual LAN Tag Properties for CMC Using Web Interface
To configure VLAN for CMC using the CMC Web interface:
1.
Go to any of the following pages:
– In the system tree, go to Chassis Overview and click Network → VLAN.
– In the system tree, go to Chassis Overview → Server Overview and click Network → VLAN.
The VLAN Tag Settings page is displayed. VLAN tags are chassis properties. They remain with the chassis even
when a component is removed.
2.
In the CMC section, enable VLAN for CMC, set the priority and assign the ID. For more information about the fields,
see the
CMC Online Help
.
3.
Click Apply. The VLAN tag settings are saved.
You can also access this page from the Chassis Overview → Servers → Setup → VLAN subtab.
Configuring Virtual LAN Tag Properties for CMC Using RACADM
1.
Enable the VLAN capabilities of the external chassis management network:
racadm config -g cfgLanNetworking -o
cfgNicVLanEnable 1
2.
Specify the VLAN ID for the external chassis management network:
racadm config -g cfgLanNetworking -o cfgNicVlanID
The valid values for
For example:
racadm config -g cfgLanNetworking -o cfgNicVlanID
1
80