Dell POWEREDGE M1000E User Manual
Page 242

Severity
Message
Cause
Critical
Mezz B
sensor for Mezz B
was asserted.
Incorrect Mezzanine card installed for IO fabric.
Critical
Mezz C
sensor for Mezz C
was asserted.
Incorrect Mezzanine card installed for IO fabric.
Critical
Drive
Storage Drive was removed.
Critical
Fault detected on Drive
Storage Drive failed.
Critical
The system board fail-safe voltage is outside
of the allowable range.
This event is generated when the system board
voltages are not at normal levels.
Critical
The watchdog timer expired.
The iDRAC watchdog timer expires and no action is
set.
Critical
The watchdog timer reset the system.
The iDRAC watchdog detected that the system has
crashed (timer expired because no response was
received from Host) and the action is set to reboot.
Critical
The watchdog timer powered off the system.
The iDRAC watchdog detected that the system has
crashed (timer expired because no response was
received from Host) and the action is set to power
off.
Critical
The watchdog timer power cycled the system. The iDRAC watchdog detected that the system has
crashed (timer expired because no response was
received from Host) and the action is set to power
cycle.
Critical
Log is full.
The SEL device detects that only one entry can be
added to the SEL before it is full.
Warning
Persistent correctable memory errors
detected on a memory device at location
Warning
Persistent correctable memory error rate has
increased for a memory device at location
Correctable ECC errors reach a critical rate.
Critical
Multi-bit memory errors detected on a memory
device at location
An uncorrectable ECC error was detected.
Critical
An I/O channel check NMI was detected on a
component at bus
function
A critical interrupt is generated in the I/O Channel.
Critical
An I/O channel check NMI wa detected on a
component at slot
A critical interrupt is generated in the I/O Channel.
Critical
A PCI parity error was detected on a
component at bus
function
Parity error was detected on the PCI bus.
242