Dell POWEREDGE M1000E User Manual
Page 117

To obtain the mask value, use a scientific calculator in hex mode and add the second values of the individual masks
(1, 2, 4, and so on) using the
For example, to enable trap alerts for Battery Probe Warning (0x2) , Power Supply Failure (0x1000) , and KVM failure
(0x80000) , key 2
The resulting hex value is 81002, and the mask value for the RACADM command is 0x81002.
Table 17. Event Traps Filter Masks
Event
Filter Mask Value
Fan Probe Failure
0x1
Battery Probe Warning
0x2
Temperature Probe Warning
0x8
Temperature Probe Failure
0x10
Redundancy Degraded
0x40
Redundancy Lost
0x80
Power Supply Warning
0x800
Power Supply Failure
0x1000
Power Supply Absent
0x2000
Hardware Log Failure
0x4000
Hardware Log Warning
0x8000
Server Absent
0x10000
Server Failure
0x20000
KVM Absent
0x40000
KVM Failure
0x80000
IOM Absent
0x100000
IOM Failure
0x200000
Firmware Version Mismatch
0x400000
Chassis Power Threshold Error
0x1000000
SDCARD Absent
0x2000000
SDCARD Error
0x4000000
Chassis Group Error
0x8000000
Server Sleeve Absent
0x10000000
Fabric Mismatch
0x20000000
4.
Enable traps alerts:
racadm config -g cfgTraps -o cfgTrapsEnable 1 -i
where
destinations for traps alerts. Destinations may be specified as appropriately formatted numeric addresses (IPv6 or
IPv4), or Fully-Qualified Domain Names (FQDNs).
117