Dell POWEREDGE M1000E User Manual

Page 215

background image

where <

value

> is a number between 2715–16685 representing the maximum power limit in Watts. The default is

16685.
For example, the following command sets the System Input Power Cap to 5400 watts:
racadm config -g cfgChassisPower -o cfgChassisPowerCap 5400

.

– To enable or disable dynamic PSU engagement, type:

racadm config -g cfgChassisPower -o cfgChassisDynamicPSUEngagementEnable

<value>

where <

value

> is 0 (disable), 1 (enable). The default is 0.

For example, the following command disables dynamic PSU engagement:
racadm config -g cfgChassisPower -o cfgChassisDynamicPSUEngagementEnable 0

.

– To enable the Max Power Conservation Mode, type:

racadm config -g cfgChassisPower -o cfgChassisMaxPowerConservationMode 1

– To restore normal operation, type:

racadm config -g cfgChassisPower -o cfgChassisMaxPowerConservationMode 0

– Enable 110 VAC PSUs:

racadm config -g cfgChassisPower -o cfgChassisAllow110VACOperation 1

– Enable Server Performance Over Power Redundancy:

racadm config -g cfgChassisPower -o cfgChassisPerformanceOverRedundancy 1

– Disable Server Performance Over Power Redundancy:

racadm config -g cfgChassisPower -o cfgChassisPerformanceOverRedundancy 0

– To enable the power remote logging feature, type the following command:

racadm config -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingEnabled 1

– To specify the desired logging interval, type the following command:

racadm config -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingInterval n

where n is 1-1440 minutes.

– To determine if the power remote logging feature is enabled, type the following command:

racadm getconfig -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingEnabled

– To determine the power remote logging interval, type the following command:

racadm getconfig -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingInterval

The power remote logging feature is dependent on remote syslog hosts having been previously configured.
Logging to one or more remote syslog hosts must be enabled, otherwise power consumption is logged. This can
be done either through the Web interface or the RACADM CLI. For more information, see the remote syslog
configuration instructions in the

RACADM Command Line Reference Guide for iDRAC7 and CMC

at dell.com/

support/manuals.

– To enable remote power management using the Dell OpenManage Power Center, type:

racadm config -g cfgChassisPower -o cfgChassisServerBasedPowerMgmtMode 1

– To restore CMC power management, type:

racadm config -g cfgChassisPower -o cfgChassisServerBasedPowerMgmtMode 0

For information about RACADM commands for chassis power, see the config, getconfig, getpbinfo, and
cfgChassisPower sections in the

RACADM Command Line Reference Guide for iDRAC7 and CMC

.