Lcd module and server status information – Dell POWEREDGE M1000E User Manual
Page 243

Severity
Message
Cause
Critical
A PCI parity error was detected on a
component at slot
Parity error was detected on the PCI bus.
Critical
A PCI system error was detected on a
component at bus
function
PCI error detected by device.
Critical
A PCI system error was detected on a
component at slot
PCI error detected by device.
Critical
Persistent correctable memory error logging
disabled for a memory device at location
Single bit error logging is disable when too many
SBE get logged for a memory device.
Critical
All event logging is disabled.
Non-
Recoverable
CPU protocol error detected.
The processor protocol entered a non-recoverable
state.
Non-
Recoverable
CPU bus parity error detected.
The processor bus PERR entered a non-
recoverable state.
Non-
Recoverable
CPU initialization error detected.
The processor initialization entered a non-
recoverable state.
Non-
Recoverable
CPU machine check detected.
The processor machine check entered a non-
recoverable state.
Critical
Memory redundancy is lost.
Critical
A bus fatal error was detected on a
component at bus
function
Fatal error is detected on the PCIe bus.
Critical
A software NMI was detected on a component
at bus
Chip error is detected.
Critical
Failed to program virtual MAC address on a
component at bus
function
Flex address could be programmed for this device.
Critical
Device option ROM on mezzanine card
FlexAddress.
Option ROM does not support Flex address or
linking tuning.
Critical
Failed to get Link Tuning or FlexAddress data
from iDRAC.
NOTE: For information on other server related LCD messages, see "Server User Guide".
LCD Module and Server Status Information
The tables in this section describe status items that are displayed on the front panel LCD for each type of component in
the chassis.