PSU Configuration
Dynamic PSU
Engagement
Firmware Response
Power Supply
Redundancy
Enabled
CMC alerts you of loss of Power Supply Redundancy. PSUs in
standby mode (if any) are turned on to compensate for power
budget lost from PSU failure or removal.
No Redundancy
Enabled
Decrease power to low priority servers, if needed.
Power Supply and Redundancy Policy Changes in System Event Log
Changes in the power supply state and power redundancy policy are recorded as events. Events related to the power
supply that record entries in the system event log (SEL) are power supply insertion and removal, power supply input
insertion and removal, and power supply output assertion and de-assertion.
The following table lists the SEL entries that are related to power supply changes:
Table 40. SEL Events for Power Supply Changes
Power Supply Event
System Event Log (SEL) Entry
Insertion
Power supply <
number
> is present.
Removal
Power supply <
number
> is absent.
Grid or Power Supply Redundancy lost
Power supply redundancy is lost.
Grid or Power Supply Redundancy regained
The power supplies are redundant.
Input power received
The input power for power supply <
number
> has been restored.
Input power lost
The input power for power supply <
number
> has been lost.
DC output produced
Power supply <
number
> is operating normally.
DC output lost
Power supply <
number
> failed.
Input over-voltage
An over voltage fault detected on power supply <
number
>.
Input under-voltage
An under voltage fault detected on power supply <
number
>.
Input over-current
An over current fault detected on power supply <
number
>.
Input under-current
An undercurrent fault detected on power supply <
number
>.
DC output under-voltage
An output under voltage fault detected on power supply <
number
>
DC output over-current
An output over current fault detected on power supply <
number
>.
DC output under-current
An output under current fault detected on power supply <
number
>.
Communication failure
Cannot communicate with power supply <
number
>.
Communication restored
Communication has been restored to power supply <
number
>.
Failure to communicate status data
Cannot obtain status information from power supply <
number
>.
Status data communication restored
Power supply
Over/Under-temperature
The temperature for power supply <
number
> is outside of range.
Fan or Airflow error/warning
Fan failure detected on power supply <
number
> .
Fan speed overridden
Fan failure detected on power supply <
number
> .
Manufacturing fault
Power supply <
number
> failed.
Microprocessor busy
Power supply <
number
> failed.
210