3 set number of bays and consoles, 4 program remote consoles – Unitec POS4000/V2-Wash Select II User Manual
Page 63

P O S 4 0 0 0
Document Number:
POS4007
37
Document Title:
POS4000/V2 WSII Operations Manual
[3]
(password
3)
[MENU UP/DOWN] until "Multiple Unit MENU->" appears
[ENTER]
[MENU UP/DOWN] until "Controller/Remote" appears
[ENTER]
[2]
to select Remote
[ENTER]
Note:
The default is for the console unit to be a controller.
4 . 1 . 1 1 . 3 S e t N u m b e r o f B a y s a n d C o n s o l e s
This command is used to define the number of customer interfaces (carwash bays) and remote
POS4000s that are present at a site.
Note:
Do not include the controller POS4000 when counting the number of Remote
POS4000s.
To select this command, scroll through the Multiple Unit sub-menu until "Set # Bays/Consoles"
appears and then press [ENTER].
Example to setup a controller console to communicate with 2 customer interfaces and 1 remote
POS4000:
[CMD]
[SYSTEM SETUP]
[3]
(password
3)
[MENU UP/DOWN] until "Multiple Unit MENU->" appears
[ENTER]
[MENU UP/DOWN] until "Set # Bays/Consoles" appears
[ENTER]
[2][ENTER]
2 bays
[1][ENTER] 1
remote
console
Note:
The default is 1 bay and 0 remote consoles.
Note:
When setting up a remote console, # of remote consoles is always set to 0.
4 . 1 . 1 1 . 4 P r o g r a m
R e m o t e
C o n s o l e s
This command is used to program or download information from the controller POS4000 to
remote POS4000s.
To select this command, scroll through the Multiple Unit sub-menu until "Prog Remote Consoles"
appears and then press [ENTER].