7 set languages, 8 set program relays, Set languages – Unitec POS4000/V2-Wash Select II User Manual
Page 54: Set program relays
P O S 4 0 0 0
Document Number:
POS4007
28
Document Title:
POS4000/V2 WSII Operations Manual
Note:
The new Baud Rate will not take effect until a power reset of the console occurs. To do
this, simply turn the ON/OFF switch in the OFF position for a moment and then return it
to the ON position.
Note:
The factory default baud rate is dependent on what type of EXT POS interface is
configured on default. Serial Baud default for POS1 & POS2 is 19200, serial baud for
POS 0 (No EXT POS interface) and POS3 is 2400.
4.1.7 Set Languages
This command allows you to change the language used on the main console display and/or the
customer language (used on tickets and optional customer display at entrance of wash). To
select this command scroll through the system configuration main menu until "Set Language"
appears and then press [ENTER].
Once selected you are prompted to enter the desired console language. Press [0][ENTER] for
English or [1][ENTER] for French. Next, you are prompted to select the customer language in a
similar manner.
Example to set console language as English and the customer language as German:
[CMD]
[SYSTEM SETUP]
[3]
(password 3)
[MENU UP/DOWN] until "Set Languages" appears
[ENTER]
[0]
for
English
[ENTER]
[2]
for
German
[ENTER]
4.1.8 Set Program Relays
This command is only available on systems configured for a specific manufacturer. If a section
titled "OUTPUT Logic Block" does not appear on your SYSTEM CONFIGURATION report then
this option is not available on your system.
This command allows the output relays on the customer interface board to be configured for
Logic and Block values that correspond to each carwash program. To select this command, scroll
through the system configuration secondary menu until "Set Program Relays" is display and
press the [ENTER] key.
Once this item is selected, you will be prompted to Enter Program Number. Use the numbers
printed on the management keys to select the number of the program you wish to configure (do
not use the cashier keys) and then press [ENTER]. Next you will be prompted to Enter Logic &
Block. Again, use the management keys to enter the appropriate value. If you enter and invalid
logic or block value, the console will display the message "Invalid Logic/Block" and the command
will be terminated.
Example to configure Program 1 to have a logic & block value of 32:
[CMD]
[SYSTEM SETUP]
[3]
(password
3)
[MENU UP/DOWN] until "Set Program Relays" appears
[ENTER]