3 set pos max washes, 4 set send code age – Unitec POS4000/V2-Wash Select II User Manual
Page 59

P O S 4 0 0 0
Document Number:
POS4007
33
Document Title:
POS4000/V2 WSII Operations Manual
[3][ENTER]
Note:
If the external POS type is set to 1 or 2, the current EXT POS settings will print out with
a mapping of the Carwash type given vs. the carwash type requested.
4 . 1 . 1 0 . 3 S e t P O S M A X W A S H E S
Note:
This feature is for use with POS 1 and 2 only.
This function is used to modify the commands received by an external point of
sale device such as pump equipment. These commands are configured to ask for
more wash types than are available. You should only change this value when
instructed to do so from an application note or a Unitec service technician. The
default value is 0 (disabled). This value only limits the number of wash types that
can be requested by an External POS device, not the number of wash types that
can be sold via the console or entry system (cash or buy ups).
Example to set the POS MAX WASHES to 3 (max of 3 washes allowed):
[CMD]
[SYSTEM SETUP]
[3]
(password
3)
[MENU UP/DOWN] until "External POS MENU->" appears
[ENTER]
[MENU UP/DOWN] until "Set POS MAX WASHES" appears
[ENTER]
[3][ENTER]
to select maximum of 3 wash types to be given
Note:
The current EXT POS settings will print out with a mapping of the carwash type given
vs. the carwash type requested.
4 . 1 . 1 0 . 4 S e t S e n d C o d e A g e
This command is used to enable the POS1 or POS2 protocol to include the response code for
code age and wash status. In some cases when this feature is not enabled (default) the receipt
printed out at the gas pump will show that the code is valid for 1 day only. Enabling this value may
cause the system to not work properly with some point of sale manufacturers. To select this
command, scroll through the External POS sub-menu until “Set Send Code Age” appears and
then press the indicated function key.
Example to set send code age enabled:
[CMD]
to select command mode
[2-System Setup]
to select "System Setup" menu
[3]
Enter your password 3
[ENTER]
[Menu up]
Until you see: "Ext. POS MENU->"
[Menu up]
Until you see “Set Send Code Age”
[Enter]
Select
function
[ 1 ]
To enable set send code age