Cable, Control
Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013
61
If [Bus Reg Mode A], parameter 161 is set to “Both-DB 1st”
Both regulators are enabled, and the operating point of the Dynamic Brake
Regulator is lower than that of the Bus Voltage Regulator. The Bus Voltage
Regulator setpoint follows the “DB Turn On” curve (
). The Dynamic
Brake Regulator follows the “DB Turn On” and turn off curves (
). For
example, with a DC Bus Memory at 684V DC, the Bus Voltage Regulator
setpoint is 750V DC and the Dynamic Brake Regulator will turn on at 750V DC
and back off at 742V DC.
Table 4
Cable, Control
Refer to “
Wiring and Grounding Guidelines for Pulse Width Modulated (PWM)
AC Drives,” publication DRIVES-IN001 for detailed information on Cable,
Control.
Cable, Motor Lengths
Refer to “
Wiring and Grounding Guidelines for Pulse Width Modulated (PWM)
AC Drives,” publication DRIVES-IN001 for detailed information on Cable,
Motor Lengths.
Cable, Power
Refer to “
Wiring and Grounding Guidelines for Pulse Width Modulated (PWM)
AC Drives,” publication DRIVES-IN001 for detailed information on Cable,
Power.
Cable Trays and Conduit
Refer to “
Wiring and Grounding Guidelines for Pulse Width Modulated (PWM)
AC Drives,” publication DRIVES-IN001 for detailed information on Cable
Trays and Conduit.
Voltage Class
DC Bus Memory
Bus Reg Curve #1
Bus Reg Curve #2
240
< 325V DC
Memory + 50V DC
Curve 1 – 4V DC
325V DC
≤
DC Bus Memory
≤
342V DC
375V DC
> 342V DC
Memory + 33V DC
480
< 650V DC
Memory + 100V DC
Curve 1 – 8V DC
650V DC
≤
DC Bus Memory
≤
685V DC
750V DC
> 685V DC
Memory + 65V DC
600
< 813V DC
Memory + 125V DC
Curve 1 – 10V DC
813V DC
≤
DC Bus Memory
≤
856V DC
937V DC
> 856V DC
Memory + 81V DC
600/690V
PowerFlex 700
Frames 5 & 6 Only
< 933V DC
Memory + 143V DC
Curve 1 – 11V DC
933V DC
≤
DC Bus Memory
≤
983V DC
1076V DC
> 983V DC
Memory + 93V DC