Page 178

Start-Up
178
Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013
Figure 40 PowerFlex 70 & 700 Standard Control Option Startup
Basic Start Up (Top Level)
Main Menu:
Parameter
Device Select
Memory Storage
StartUp
Preferences
No
PowerFlex 70
StartUp .
Complete these
steps in order:
1. Input Voltage
2. Motr Dat/Ramp
3. Motor Tests
4. Speed Limits
5. Speed Control
6. Strt,Stop,I/O
7. Done / Exit
0-0
PowerFlex 70
StartUp .
Make a selection
Abort
Resume
StartUp Menu
Resume
Startup Menu
0-3
HIM
7. Done
/Exit
Go to 2-0
Go to 4-0
Go to 5-0
2. Motor
Dat/Ramps
6. Strt,Stop,
I/O
4. Speed
Limits
Backup
'Esc' key
Go to 3-0
3. Motor
Tests
Go to 1-0
1. Input
Voltage
Go to 6-0
5. Speed
Control
PowerFlex 70
StartUp .
This routine is
to help setup a
drive for basic
applications.
Parameter access
through other
menus may be
necessary to
setup advanced
features.
0-1
PowerFlex 70
StartUp .
The drive must
be stopped to
proceed. Press
Esc to cancel.
0-2
Drive active?
Startup
Yes
Startup
previously
aborted?
No
Abort
Yes
Stop
Esc
Enter
Backup
Any state
Go to previous
state
Go to Backup
screen for previous
state