beautypg.com

Connecting a powered sensor – Rockwell Automation 1440-VSE02-01RA XM-122 gSE Vibration Module User Manual

Page 195

background image

Publication GMSI10-UM013D-EN-P - May 2010

Wiring Connections for Previous Module Revisions 185

Connecting a Powered Sensor

Figures D.6 and D.7 show the wiring of a powered sensor, such as the Model
580 Vibration Pickup, to an earlier version of the XM-122 module (before
D01).

Figure D.6 Powered Sensor to Channel 1 Wiring

ATTENTION

You may ground the cable shield at either end of the cable.
Do not ground the shield at both ends. Recommended
practice is to ground the cable shield at the terminal base
and not at the transducer. Any convenient Chassis terminal
may be used (see Terminal Block Assignments on page
179).

0

16

37

+24V DC

Common

Signal

5

6

21

22

Channel 1 Input Signal

Signal Common

Shield

+24V DC

TYPICAL WIRING FOR MODEL 580 VIBRATION PICKUP

TO XM-122 VIBRATION MODULE CHANNEL 1

Cable shield not