Rockwell Automation 1440-VSE02-01RA XM-122 gSE Vibration Module User Manual
Page 139

Publication GMSI10-UM013D-EN-P - May 2010
DeviceNet Objects 129
Instance 105 - Measurement Values
This Assembly instance can be selected to be sent in response to an I/O Poll
request from a Master.
48 - 51
Channel 1 Band 1 value
52 - 55
Channel 2 Band 1 value
56 - 59
Channel 1 Band 2 value
60 - 63
Channel 2 Band 2 value
64 - 67
Channel 1 Not 1X value (AIP Object Instance #3)
68 - 71
Channel 2 Not 1X value (AIP Object Instance #4)
72 - 75
Channel 1 Band 3 value
76 - 79
Channel 2 Band 3 value
80 - 83
Channel 1 Band 4 value
84 - 87
Channel 2 Band 4 value
88 - 91
Channel 1 gSE Overall value (AIP Object Instance #5)
92 - 95
Channel 2 gSE Overall value (AIP Object Instance #6)
96 - 99
Channel 1 Vector 3 Magnitude value
100 - 103
Channel 2 Vector 3 Magnitude value
104 - 107
Channel 1 Vector 2 Phase value
108 - 111
Channel 2 Vector 2 Phase value
112 - 115
Channel 1 Sum Harmonics value (AIP Object Instance #7)
116 - 119
Channel 2 Sum Harmonics value (AIP Object Instance #8)
120 - 123
Maximum Speed value
Table C.14 Instance 104 Data Format (Measurement Values Assembly)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Table C.15 Instance 105 Data Format (Measurement Values Assembly)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0 - 3
Channel 1 gSE Overall value (AIP Object Instance #5)
4 - 7
Channel 2 gSE Overall value (AIP Object Instance #6)
8 - 11
Channel 1 Overall value
12 - 15
Channel 2 Overall value
16 - 19
Speed value
20 - 23
Acceleration value
24 - 27
Channel 1 Vector 1 Magnitude value
28 - 31
Channel 2 Vector 1 Magnitude value
32 - 35
Channel 1 Vector 2 Magnitude value
36 - 39
Channel 2 Vector 2 Magnitude value