20 ma output object (class id 32ah), Class attributes, Instances – Rockwell Automation 1440-VSE02-01RA XM-122 gSE Vibration Module User Manual
Page 186: Class attributes instances, 20 ma output object (class id 32a, Services

Publication GMSI10-UM013D-EN-P - May 2010
176 DeviceNet Objects
Services
4-20 mA Output Object
(Class ID 32A
H
)
The 4-20 mA Output Object models the configuration of a 4-20 mA output
signal.
Class Attributes
The 4-20 mA Output Object provides no class attributes.
Instances
There are 2 instances of this object.
6
Get
Magnitude Data
Units
ENGUNIT
The units context of the
Magnitude Value
attribute.
This setting is determined by the
Channel Object’s Output Data
Units setting (see page 153).
7
Get
Speed Value
REAL
The speed at which the
magnitude and phase are
measured.
Instances 1 and 2 use 1X
machine speed.
Instances 3 and 4 use 2X
machine speed.
Instances 5 and 6 use 3X
machine speed.
The value is only valid when
synchronous sampling mode is
selected for the corresponding
channel.
8
Get
Speed Data
Units
ENGUNIT
The units context of the
Speed Value attribute.
See DeviceNet Specification
Volume 1 Appendix K.
This is set to Orders (0x0B00).
Table C.65 Vector Measurement Object Instance Attributes
Attr ID
Access
Rule
Name Data
Type
Description
Semantics
Table C.66 Vector Measurement Object Services
Service
Code
Class/Instance Usage
Name
Description
0E
h
Instance
Get_Attribute_Single
Returns a single attribute.