DeviceNet Objects 127
Instance 103 - Measurement Values
This assembly instance can be selected to be sent in response to an I/O Poll
request from a Master. This instance includes all of the non-speed related
measurements first.
72 - 75
Channel 2 Band 1 value
76 - 79
Channel 2 Band 2 value
80 - 83
Channel 2 Vector 1 Magnitude value
84 - 87
Channel 2 Vector 2 Magnitude value
88 - 91
Channel 2 Vector 3 Magnitude value
92 - 95
Channel 2 Band 3 value
96 - 99
Channel 2 Band 4 value
100 - 103
Channel 2 Vector 1 Phase value
104 - 107
Channel 2 Vector 2 Phase value
108 - 111
Channel 2 Gap value (AIP Object Instance #2)
112 - 115
Channel 2 Not 1X value (AIP Object Instance #4)
116 - 119
Channel 2 Sum Harmonics value (AIP Object Instance #8)
120 - 123
Maximum Speed value
Table C.12 Instance 102 Data Format (Measurement Values Assembly)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Table C.13 Instance 103 Data Format (Measurement Values Assembly)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0 - 3
Channel 1 Band 1 value
4 - 7
Channel 2 Band 1 value
8 - 11
Channel 1 Band 2 value
12 - 15
Channel 2 Band 2 value
16 - 19
Channel 1 Overall value
20 - 23
Channel 2 Overall value
24 - 27
Channel 1 Band 3 value
28 - 31
Channel 2 Band 3 value
32 - 35
Channel 1 Band 4 value
36 - 39
Channel 2 Band 4 value
40 - 43
Channel 1 Gap value (AIP Object Instance #1)
44 - 47
Channel 2 Gap value (AIP Object Instance #2)
48 - 51
Channel 1 gSE Overall value (AIP Object Instance #5)
52 - 55
Channel 2 gSE Overall value (AIP Object Instance #6)
56 - 59
Channel 1 Sum Harmonics value (AIP Object Instance #7)