Customer interface board (cont.) – Rockwell Automation 7000 PowerFlex Medium Voltage AC Drive (B Frame) - Classic Control User Manual
Page 380
6-90
Component Definition and Maintenance
7000-UM150I-EN-P – June 2013
7000 “B” Frame
The following table illustrates the most commonly used test points.
New SCB Board
(80190-378-xx)
Old SCB Board
(80190-278-xx)
Description
TP #
Label
TP #
Label
3
VBCXFR_OUT
1
VBCXFR_OUT
Voltage BC on Line Side of Bypass Contactor, unfiltered
4
VABXFR_OUT
2
VABXFR_OUT
Voltage AB on Line Side of Bypass contactor, unfiltered
5
VAB2_OUT
3
VAB2_OUT
Voltage AB on Slave 1 input winding, unfiltered
6
VBC2_OUT
4
VBC2_OUT
Voltage BC on Slave 1 input winding, unfiltered
7
VCA2_OUT
5
VCA2_OUT
Voltage CA on Slave 1 input winding, unfiltered
8
VAB3_OUT
6
VAB3_OUT
Voltage AB on Slave 2 input winding, unfiltered
9
VBC3_OUT
7
VBC3_OUT
Voltage BC on Slave 2 input winding, unfiltered
10
VCA3_OUT
8
VCA3_OUT
Voltage CA on Slave 2 input winding, unfiltered
11
VAB1_OUT
9
VAB1_OUT
Voltage AB on Master input winding (SCBL) or Motor (SCMB), unfiltered
12
VBC1_OUT
10
VBC1_OUT
Voltage BC on Master input winding (SCBL) or Motor (SCBM), unfiltered
13
VCA1_OUT
11
VCA1_OUT
Voltage CA on Master input winding (SCBL) or Motor (SCBM), unfiltered
14
VDC_AVG
12
VDC_AVG
DC Link Average Voltage across Inverter Side (SCBL only), calculated
28
-15V
24
-15V
-15V DC Analog Power
29
AGND
25
AGND
Analog Power Common
30
+15V
26
+15V
+15V DC Analog Power
31
-24V
27
-24V
-24V DC Hall-Effect Transducer Power
32
LEMGND
28
LEMGND
Hall-Effect Transducer Power Common
33
+24V
29
+24V
+24V DC Hall-Effect Transducer Power
34
+5V
30
+5V
+5V DC Digital Power
35
DGND
31
DGND
Digital Power Common
36
VN
32
VN
Voltage from Filter Capacitor Neutral Point, unfiltered
38
VNG
35
VNG
Converter Neutral-Ground Voltage, calculated
64
IDCP
42
IDCP
DC Link Current Feedback, filtered
66
IFIELD
45
IFIELD
Synchronous Motor Field Current Feedback, filtered
74
DAC_TP1
76
DAC_TP1
Assignable Test Point (Rect_TP1 [SCBL] or INV_TP1 [SCMB] parameters)
75
DAC_TP1
77
DAC_TP1
Assignable Test Point (Rect_TP2 [SCBL] or INV_TP2 [SCMB] parameters)
1
IA1_OUT
N/A
Across R17
Current Phase A, Master Bridge, unfiltered
2
IC1_OUT
N/A
Across R29
Current Phase C, Master Bridge, unfiltered
15
IA2_OUT
N/A
Across R33
Current Phase A, Slave 1 Bridge, unfiltered
27
IC2_OUT
N/A
Across R66
Current Phase C, Slave 1 Bridge, unfiltered
40
IA3_OUT
N/A
Across R75
Current Phase A, Slave 2 Bridge (SCBL) or Motor (SCBM), unfiltered
41
IC3_OUT
N/A
Across R89
Current Phase C, Slave 2 Bridge (SCBL) or Motor (SCBM), unfiltered
62
IDCP_OUT
N/A
Across R138
DC Link Feedback Current (SCBL), unfiltered
70
IGND_OUT
N/A
Across R140
Zero Sequence Feedback Current (SCBL), unfiltered
75
IFIELD_OUT
N/A
Across R156
Field Current Feedback (SCBL), unfiltered
67
DOUT0
63
DOUT0
Digital Output command for DI Contactor (SCBL) or Bypass Contactor (SCBM)
65
DOUT1
62
DOUT1
Digital Output Command for Bypass Enable (SCBM)
60
DOUT3
69
DOUT3
Digital Output Command for DO Contactor (SCBL) or OP Contactor (SCBM)
55
DIN0
N/A
Digital Input Status for DI Contactor (SCBL) or Bypass Ctctr (SCBM)
53
DIN1
N/A
Digital Input Status for DI Isolation Switch (SCBL) or Bypass Isol. Sw. (SCBM)
50
DIN2
N/A
Digital Input Status for OP Contactor (SCBL) or OP Contactor (SCBM)
47
DIN3
N/A
Digital Input Status for OP Isolation Switch (SCBL) or OP Isol. Sw. (SCBM)
44
ENCA
N/A
Pulse Train from the Input of the Encoder Signal, Channel A
45
ENCB
N/A
Pulse Train from the Input of the Encoder Signal, Channel B
Requires the usage of isolated probes or isolation channels on the oscilloscope to avoid damaging the PF7000 Drive.
Customer Interface Board