Rockwell Automation 1403-NDNET DeviceNet Communications Card Installation Instructions User Manual
Page 122
![background image](/manuals/578851/122/background.png)
Publication 1403-IN054B-EN-P - August 2001
B-92 DeviceNet Data Tables
Instance 2 Attributes (Predefined Master/Slave Polled I/O
Message Connection)
14
Get
Produced Connection Path
Array of USINT
null (no data)
15
Get
Consumed Connection Path
Length
UINT
0
16
Get
Consumed Connection Path
Array of USINT
null (no data)
17
Get
Production Inhibit TIme
UINT
0
Attribute ID
Access Rule
Name
DeviceNet Data
Type
Data Value
Attribute ID
Access Rule
Name
DeviceNet
Data Value
1
Get
State
USINT
0=nonexistent 1=configuring
(default) 2=waiting for
connection ID 3=established
4=timed out 5=deferred delete
2
Get
Instance Type
USINT
1=I/O message
3
Get
Transport Class Trigger
Byte
0x82 or 0x83
4
Get
Produced Connection ID
UINT
01111xxxxxx
xxxxxx=node address
5
Get
Consumed Connection ID
UINT
10xxxxxx101
xxxxxx=node address
6
Get
Initial Comm Characteristics
Byte
0x01
7
Get
Produced Connection Size
UINT
8
8
Get
Consumed Connection Size
UINT
4
9
Get/Set
Expected Packet Rate
UINT
0 default
12
Get
Watchdog Timeout Action
USINT
0=timeout (default) 1=auto
delete 2=auto reset
13
Get
Produced Connection Path
Length
UINT
6
14
Get
Produced Connection Path
LogicalSegment, Class
Class Number
Logical Segment, Instance
Instance Number
Logical Segment, Attribute
Attribute Number
Array of:
USINT
0x20
0x04
0x24
0x01
0x30
0x03
15
Get
Consumed Connection Path
Length
UINT
6
16
Get
Consumed Connection Path
Logical Segment,Class
Class Number
Logical Segment, Instance
Instance Number
Logical Segment, Attribute
Attribute Number
Array of:
USINT
0x20
0x04
0x24
0x02
0x30
0x03
17
Get
Production Inhibit Time
UINT
0