800
28
th
harmonic
Float
4
See Instance 42, parameter 4 (phase angle for V3)
801
29
th
harmonic
Float
4
See Instance 44, parameter 4 (phase angle for V3)
802
30
th
harmonic
Float
4
See Instance 42, parameter 5 (phase angle for V3)
803
31
st
harmonic
Float
4
See Instance 44, parameter 5 (phase angle for V3)
804
32
nd
harmonic
Float
4
See Instance 42, parameter 6 (phase angle for V3)
805
33
rd
harmonic
Float
4
See Instance 44, parameter 6 (phase angle for V3)
806
34
th
harmonic
Float
4
See Instance 42, parameter 7 (phase angle for V3)
807
35
th
harmonic
Float
4
See Instance 44, parameter 7 (phase angle for V3)
808
36
th
harmonic
Float
4
See Instance 42, parameter 8 (phase angle for V3)
809
37
th
harmonic
Float
4
See Instance 44, parameter 8 (phase angle for V3)
810
38
th
harmonic
Float
4
See Instance 42, parameter 9 (phase angle for V3)
811
39
th
harmonic
Float
4
See Instance 44, parameter 9 (phase angle for V3)
812
40
th
harmonic
Float
4
See Instance 42, parameter 10 (phase angle for V3)
813
41
st
harmonic
Float
4
See Instance 44, parameter 10 (phase angle for V3)
814
IEEE THD
Float
4
See Instance 40, parameter 1 (for I3)
815
IEC thd
Float
4
See Instance 40, parameter 2 (for I3)
816
TIF
Float
4
See Instance 40, parameter 3 (for I3)
817
Crest factor
Float
4
See Instance 40, parameter 4 (for I3)
818
K-factor
Float
4
See Instance 40, parameter 5 (for I3)
819
IEEE 519 pass/fail
Int
4
See Instance 40, parameter 6 (for I3)
820
Fundamental
Float
4
See Instance 43, parameter 1 (% harmonic distortion for I3)
821
2
nd
harmonic
Float
4
See Instance 41, parameter 2 (% harmonic distortion for I3)
822
3
rd
harmonic
Float
4
See Instance 43, parameter 2 (% harmonic distortion for I3)
823
4
th
harmonic
Float
4
See Instance 41, parameter 3 (% harmonic distortion for I3)
824
5
th
harmonic
Float
4
See Instance 43, parameter 3 (% harmonic distortion for I3)
825
6
th
harmonic
Float
4
See Instance 41, parameter 4 (% harmonic distortion for I3)
826
7
th
harmonic
Float
4
See Instance 43, parameter 4 (% harmonic distortion for I3)
827
8
th
harmonic
Float
4
See Instance 41, parameter 5 (% harmonic distortion for I3)
828
9
th
harmonic
Float
4
See Instance 43, parameter 5 (% harmonic distortion for I3)
829
10
th
harmonic
Float
4
See Instance 41, parameter 6 (% harmonic distortion for I3)
830
11
th
harmonic
Float
4
See Instance 43, parameter 6 (% harmonic distortion for I3)
831
12
th
harmonic
Float
4
See Instance 41, parameter 7 (% harmonic distortion for I3)
832
13
th
harmonic
Float
4
See Instance 43, parameter 7 (% harmonic distortion for I3)
833
14
th
harmonic
Float
4
See Instance 41, parameter 8 (% harmonic distortion for I3)
834
15
th
harmonic
Float
4
See Instance 43, parameter 8 (% harmonic distortion for I3)
835
16
th
harmonic
Float
4
See Instance 41, parameter 9 (% harmonic distortion for I3)
836
17
th
harmonic
Float
4
See Instance 43, parameter 9 (% harmonic distortion for I3)
837
18
th
harmonic
Float
4
See Instance 41, parameter 10 (% harmonic distortion for I3)
838
19
th
harmonic
Float
4
See Instance 43, parameter 10 (% harmonic distortion for I3)
Param # Parameter name
Data type #bytes
Comment