Rockwell Automation 1403-NDNET DeviceNet Communications Card Installation Instructions User Manual
Page 101
![background image](/manuals/578851/101/background.png)
Publication 1403-IN054B-EN-P - August 2001
DeviceNet Data Tables B-71
380
39
th
harmonic
Float
4
See Instance 44, parameter 9 (harmonic magnitude for I1)
381
40
th
harmonic
Float
4
See Instance 42, parameter 10 (harmonic magnitude for I1)
382
41
st
harmonic
Float
4
See Instance 44, parameter 10 (harmonic magnitude for I1)
383
Fundamental
Float
4
See Instance 43, parameter 1 (phase angle for I1)
384
2
nd
harmonic
Float
4
See Instance 41, parameter 2 (phase angle for I1)
385
3
rd
harmonic
Float
4
See Instance 43, parameter 2 (phase angle for I1)
386
4
th
harmonic
Float
4
See Instance 41, parameter 3 (phase angle for I1)
387
5
th
harmonic
Float
4
See Instance 43, parameter 3 (phase angle for I1)
388
6
th
harmonic
Float
4
See Instance 41, parameter 4 (phase angle for I1)
389
7
th
harmonic
Float
4
See Instance 43, parameter 4 (phase angle for I1)
390
8
th
harmonic
Float
4
See Instance 41, parameter 5 (phase angle for I1)
391
9
th
harmonic
Float
4
See Instance 43, parameter 5 (phase angle for I1)
392
10
th
harmonic
Float
4
See Instance 41, parameter 6 (phase angle for I1)
393
11
th
harmonic
Float
4
See Instance 43, parameter 6 (phase angle for I1)
394
12
th
harmonic
Float
4
See Instance 41, parameter 7 (phase angle for I1)
395
13
th
harmonic
Float
4
See Instance 43, parameter 7 (phase angle for I1)
396
14
th
harmonic
Float
4
See Instance 41, parameter 8 (phase angle for I1)
397
15
th
harmonic
Float
4
See Instance 43, parameter 8 (phase angle for I1)
398
16
th
harmonic
Float
4
See Instance 41, parameter 9 (phase angle for I1)
399
17
th
harmonic
Float
4
See Instance 43, parameter 9 (phase angle for I1)
400
18
th
harmonic
Float
4
See Instance 41, parameter 10 (phase angle for I1)
401
19
th
harmonic
Float
4
See Instance 43, parameter 10 (phase angle for I1)
402
20
th
harmonic
Float
4
See Instance 41, parameter 11 (phase angle for I1)
403
21
st
harmonic
Float
4
See Instance 43, parameter 11 (phase angle for I1)
404
22
nd
harmonic
Float
4
See Instance 42, parameter 1 (phase angle for I1)
405
23
rd
harmonic
Float
4
See Instance 44, parameter 1 (phase angle for I1)
406
24
th
harmonic
Float
4
See Instance 42, parameter 2 (phase angle for I1)
407
25
th
harmonic
Float
4
See Instance 44, parameter 2 (phase angle for I1)
408
26
th
harmonic
Float
4
See Instance 42, parameter 3 (phase angle for I1)
409
27
th
harmonic
Float
4
See Instance 44, parameter 3 (phase angle for I1)
410
28
th
harmonic
Float
4
See Instance 42, parameter 4 (phase angle for I1)
411
29
th
harmonic
Float
4
See Instance 44, parameter 4 (phase angle for I1)
412
30
th
harmonic
Float
4
See Instance 42, parameter 5 (phase angle for I1)
413
31
st
harmonic
Float
4
See Instance 44, parameter 5 (phase angle for I1)
414
32
nd
harmonic
Float
4
See Instance 42, parameter 6 (phase angle for I1)
415
33
rd
harmonic
Float
4
See Instance 44, parameter 6 (phase angle for I1)
416
34
th
harmonic
Float
4
See Instance 42, parameter 7 (phase angle for I1)
417
35
th
harmonic
Float
4
See Instance 44, parameter 7 (phase angle for I1)
Param # Parameter name
Data type #bytes
Comment