Instance attributes, Services, Scanport device object – Rockwell Automation 1203-EN1 EtherNet/IP-to-SCANport Module User Manual
Page 129: Continued)

EtherNet/IP Objects
C-19
Class Attributes (Continued)
Instance Attributes
Services
SCANport Device Object
(Continued)
Attribute
ID
Access
Rule
Name
Data Type
Description
2
Set
Language Code
BYTE
0 = English
1 = French
2 = Spanish
3 = Italian
4 = German
5 = Japanese
6 = Portuguese
7 = Mandarin Chinese
8 = Russian
9 = Dutch
3
Get
Product Series
BYTE
1 = A, 2 = B …
4
Get
Number of
Components
BYTE
Number of components (e.g., main
control board, I/O boards) in the device.
5
Set
User Definable
Text
STRING[16] Text identifying the device with a
user-supplied name
6
Get
Status Text
STRING[12] Text describing the status of the device.
7
Get
Configuration
Code
BYTE
Identification of variations.
8
Get
Configuration Text STRING[16] Text identifying variation of family device.
9
Get
Brand Code
WORD
0x0001 = Allen-Bradley
11
Get
NVS Checksum
WORD
Checksum of the Non-Volatile Storage
in a device.
128
Get
Customization
Code
WORD
Code identifying the customized device.
129
Get
Customization
Revision Number
WORD
Revision of the customized device.
130
Get
Customization
Device Text
STRING[32] Text identifying the customized device.
Attribute
ID
Access
Rule
Name
Data Type
Description
0
Get
Microprocessor
Text String
STRING[8]
Name of the component
1
Get
Microprocessor
Firmware Version
WORD
Firmware version = 100 x major
revision + minor revision
2
Get
Microprocessor
Language Module
Version
WORD
Language module version =
100 x major revision + minor
revision
Service Code
Implemented for:
Service Name
Class
Instance
0x0E
Yes
Yes
Get_Attribute_Single
0x10
Yes
Yes
Set_Attribute_Single