beautypg.com

Xtra-guard® continuous flex control – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 85

background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

113

Cable > Xtra-Guard > Xtra-Guard Flex > Multiconductor > Braid Shield > 600 V

Xtra-Guard® Continuous Flex Control

C-Track or High Flexing Applications Up to 14 Million Flex Life Cycles

600 V Shielded, Multiconductor

UL AWM 2587

CSA AWM I/II A/B FT1

CE

Operating Temperature

• -5°C to +90°C (flexing)

• -40°C to +90°C (stationary)

Conductor Color Coding

• Numbered red conductors

• 1 yellow/green ground

conductor

• Jacket color: black

Materials

• Finely stranded bare copper

conductors

• Lubricated PVC insulation

• Tinned copper braid shield,

85% coverage

• PVC inner jacket

• Oil-resistant PVC jacket

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-FLEX: Highly flexible,

cross-linked silicone rubber

• FIT-650: Chemical/

temperature resistant cross-

linked fluoroelastomer

20 AWG ( 0.51 mm

2

)

Stranding: 63/38 (63 x 0.10 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

85003CY

3

0.350

8.89

0.035

0.89

85004CY

4

0.375

9.53

0.035

0.89

85005CY

5

0.411

10.44

0.040

1.02

85007CY

7

0.482

12.24

0.040

1.02

85010CY

10

0.545

13.84

0.040

1.02

85012CY

12

0.564

14.33

0.050

1.27

85018CY

18

0.662

16.81

0.060

1.52

85025CY

25

0.812

20.62

0.070

1.78

18 AWG (0.85 mm

2

)

Stranding: 105/38 (105 x 0.10 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

85803CY

3

0.376

9.55

0.035

0.89

85804CY

4

0.414

10.52

0.040

1.02

85805CY

5

0.453

11.51

0.040

1.02

85807CY

7

0.532

13.51

0.045

1.14

85812CY

12

0.634

16.10

0.060

1.52

85818CY

18

0.725

18.42

0.060

1.52

85825CY

25

0.908

23.06

0.080

2.03

16 AWG (1.36mm

2

)

Stranding: 168/38 (168 x 0.10 mm)

Insulation thickness: 0.022 (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

85603CY

3

0.419

10.64

0.035

0.89

85604CY

4

0.460

11.68

0.040

1.02

85605CY

5

0.500

12.70

0.040

1.02

85607CY

7

0.602

15.29

0.055

1.40

85612CY

12

0.700

17.78

0.060

1.52

85615CY

15

0.769

19.53

0.060

1.52

85618CY

18

0.805

20.45

0.060

1.52

85625CY

25

0.973

24.71

0.065

1.65

85634CY

34

1.087

27.61

0.085

2.16

14 AWG (2.16mm

2

)

Stranding: 266/38 (266 x 0.10 mm)

Insulation thickness: 0.022” (0.56 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

85404CY

4

0.528

13.41

0.050

1.27

85407CY

7

0.676

17.17

0.065

1.65