beautypg.com

Xtra-guard® 4 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 52

background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

80

Cable > Xtra-Guard > Xtra-Guard 4 > Multiconductor > Unshielded > 300 V

Xtra-Guard® 4

Advanced Temperature and Chemical Performance

300 V Unshielded, Multiconductor

UL AWM 20237

UL PLTC*

CSA AWM I/II A/B FT1

MSHA P-07-KA070017-MSHA

NEC Class 1, Div 2 (22 &

20 AWG)

Operating Temperature

• –50°C to +125°C

Conductor Color Coding

• 24, 22 AWG: Chart E (page 520)

• 20, 18, 16 AWG: Chart D

(page 519)

• Nine jacket colors

(black standard)

• Custom colors available

Materials

• Stranded tinned copper

conductors

• TPE insulation

• TPE jacket

• Nylon ripcord

Availability

Made to order

1000 ft (305 m) minimum

FIT® Tubing Recommendations

• FIT-600: highly flexible,

cross-linked elastomer

• FIT-400: temperature/chemical

resistant FEP

24 AWG (0.23 mm

2

)*

Stranding: 7/32 (7 x 0.20 mm)

Insulation thickness: 0.016 (0.41 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

45012

2

0.200

5.08

0.042

1.07

45013

3

0.209

5.31

0.042

1.07

45014

4

0.224

5.69

0.042

1.07

45016

6

0.257

6.53

0.042

1.07

45018

8

0.275

6.99

0.042

1.07

45020

10

0.312

7.92

0.042

1.07

45020/15

15

0.347

8.81

0.042

1.07

45020/20

20

0.383

9.73

0.042

1.07

45020/25

25

0.424

10.77

0.042

1.07

22 AWG (0.35 mm

2

)

Stranding: 7/30 (7 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

45002

2

0.218

5.54

0.045

1.14

45003

3

0.228

5.79

0.045

1.14

45004

4

0.244

6.20

0.045

1.14

45006

6

0.281

7.14

0.045

1.14

45008

8

0.301

7.65

0.045

1.14

45010

10

0.342

8.69

0.045

1.14

45010/15

15

0.380

9.65

0.045

1.14

45010/20

20

0.441

11.20

0.055

1.40

45010/25

25

0.486

12.34

0.055

1.40

20 AWG (0.56 mm

2

)

Stranding: 7/28 (7 x 0.32

mm)

Insulation thickness: 0.016 (0.41 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

45052

2

0.234

5.94

0.045

1.14

45053

3

0.245

6.22

0.045

1.14

45054

4

0.264

6.71

0.045

1.14

45056

6

0.306

7.77

0.045

1.14

45058

8

0.328

8.33

0.045

1.14

45060

10

0.374

9.50

0.045

1.14

45060/15

15

0.437

11.10

0.055

1.40

45060/20

20

0.483

12.27

0.055

1.40

45060/25

25

0.534

13.56

0.055

1.40

* UL AWM 20237, CSA AWM I/II A/B FT1 only