Xtra-guard® 2 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual
Page 36
![background image](/manuals/569486/36/background.png)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
64
Cable > Xtra-Guard > Xtra-Guard 2 > Multiconductor > Supra-Shield Foil/Braid > 300 V
Xtra-Guard® 2
Oil and Abrasion Resistant
300 V Supra-Shield® Foil/Braid, Multiconductor
UL AWM 20668 VW-1
CSA AWM I/II A/B FT1
Operating Temperature
• –30°C to +90°C
Conductor Color Coding
• 24, 22 AWG: Chart E (page 520)
• 20, 18, 16 AWG: Chart D
(page 519)
• Nine jacket colors
(black standard)
• Custom colors available
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Specially formulated
polyurethane jacket
• UV resistant
• Supra-Shield foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
Availability
Made to order
1000 ft (305 m) minimum
FIT® Tubing Recommendations
• FIT-750: Bonding adhesive lined,
cross-linked polyolefin
24 AWG (0.23 mm
2
)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
25112
2
0.184
4.67
0.032
0.81
25113
3
0.191
4.85
0.032
0.81
25114
4
0.203
5.16
0.032
0.81
25116
6
0.229
5.82
0.032
0.81
25118
8
0.243
6.17
0.032
0.81
25120
10
0.272
6.91
0.032
0.81
25120/15
15
0.299
7.59
0.032
0.81
25120/20
20
0.328
8.33
0.032
0.81
25120/25
25
0.360
9.14
0.032
0.81
25120/30
30
0.378
9.60
0.032
0.81
25120/40
40
0.418
10.62
0.032
0.81
25120/50
50
0.457
11.61
0.032
0.81
22 AWG (0.35 mm
2
)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
25102
2
0.196
4.97
0.032
0.81
25103
3
0.204
5.18
0.032
0.81
25104
4
0.217
5.51
0.032
0.81
25106
6
0.247
6.27
0.032
0.81
25108
8
0.263
6.68
0.032
0.81
25110
10
0.296
7.52
0.032
0.81
25110/15
15
0.327
8.31
0.032
0.81
25110/20
20
0.359
9.12
0.032
0.81
25110/25
25
0.396
10.06
0.032
0.81
25110/30
30
0.417
10.59
0.032
0.81
25110/40
40
0.462
11.73
0.032
0.81
25110/50
50
0.506
12.85
0.032
0.81
20 AWG (0.56 mm
2
)
Stranding: 7/28 (7 x 0.32
mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
25152
2
0.236
5.99
0.032
0.81
25153
3
0.247
6.27
0.032
0.81
25154
4
0.266
6.76
0.032
0.81
25156
6
0.308
7.82
0.032
0.81
25158
8
0.330
8.38
0.032
0.81
25160
10
0.376
9.55
0.032
0.81
25160/15
15
0.419
10.64
0.032
0.81
25160/20
20
0.465
11.81
0.032
0.81
25160/25
25
0.516
13.11
0.032
0.81
25160/30
30
0.545
13.84
0.032
0.81
25160/40
40
0.656
16.66
0.053
1.35
25160/50
50
0.718
18.24
0.053
1.35