beautypg.com

Xtra-guard® 1 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 10

background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

38

Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Foil Shielded > 300 V

Xtra-Guard® 1

High Performance

300 V Foil Shielded, Multiconductor

UL CM

UL AWM 2464 VW-1

CSA CMG FT4

Operating Temperature

• –30°C to +80°C (AWM)

• –30°C to +105°C (CM)

Conductor Color Coding

• 28, 26, 24, 22 AWG: Chart E

(page 520)

• 20, 18, 16 AWG: Chart D (page 519)

• Jacket Colors

• Put-ups: slate

• Bulk: nine colors available

(page 31, minimums

may apply)

Materials

• Stranded tinned copper

conductors

• Premium PVC insulation

• Aluminum/polyester foil shield,

with 25% overlap and foil

facing inward

• Tinned copper drain wire sized

the same as cable conductors

• Nylon ripcord

• Premium PVC jacket

• UV resistant

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-221: General-purpose,

cross-linked polyolefin (indoor)

• FIT-321: Medium-wall,

adhesive-lined, cross-linked

polyolefin (outdoor)

28 AWG (0.09 mm

2

)

Stranding: 7/36 (7 x 0.127 mm)

Insulation thickness: 0.010 (0.25 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5926

2

0.142

3.61

0.032

0.81

5927

3

0.148

3.76

0.032

0.81

5928

4

0.157

3.99

0.032

0.81

5929

6

0.178

4.52

0.032

0.81

5930

7

0.178

4.52

0.032

0.81

5931

8

0.189

4.80

0.032

0.81

26 AWG (0.14 mm

2

)

Stranding: 7/34 (7 x 0.16 mm)

Insulation thickness: 0.010 (0.25 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5674

2

0.150

3.81

0.032

0.81

5675

3

0.156

3.96

0.032

0.81

5676

4

0.166

4.22

0.032

0.81

5677

6

0.190

4.83

0.032

0.81

5678

7

0.190

4.83

0.032

0.81

5679

8

0.202

5.13

0.032

0.81

5680

10

0.228

5.79

0.032

0.81

5681

15

0.252

6.40

0.032

0.81

24 AWG (0.23 mm

2

)

Stranding: 7/32 (7 x 0.20 mm)

Insulation thickness: 0.010 (0.25 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5092C

2

0.160

4.06

0.032

0.81

5093C

3

0.167

4.24

0.032

0.81

5094C

4

0.179

4.55

0.032

0.81

5096C

6

0.205

5.21

0.032

0.81

5098C

8

0.219

5.56

0.032

0.81

5100C

10

0.248

6.30

0.032

0.81

5100/15C

15

0.275

6.99

0.032

0.81

5100/20C

20

0.304

7.72

0.032

0.81

5100/25C

25

0.336

8.53

0.032

0.81

5100/30C

30

0.354

8.99

0.032

0.81

5100/40C

40

0.394

10.01

0.032

0.81

5100/50C

50

0.433

11.00

0.032

0.81

5100/60C

60

0.468

11.89

0.032

0.81

5100/70C

70

0.505

12.83

0.032

0.81