300 V Foil Shielded, Multiconductor
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart E
(page 520)
• 20, 18, 16 AWG: Chart D (page 519)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 31, minimums
may apply)
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Aluminum/polyester foil shield,
with 25% overlap and foil
facing inward
• Tinned copper drain wire sized
the same as cable conductors
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
28 AWG (0.09 mm
2
)
Stranding: 7/36 (7 x 0.127 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
5926
2
0.142
3.61
0.032
0.81
5927
3
0.148
3.76
0.032
0.81
5928
4
0.157
3.99
0.032
0.81
5929
6
0.178
4.52
0.032
0.81
5930
7
0.178
4.52
0.032
0.81
5931
8
0.189
4.80
0.032
0.81
26 AWG (0.14 mm
2
)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
5674
2
0.150
3.81
0.032
0.81
5675
3
0.156
3.96
0.032
0.81
5676
4
0.166
4.22
0.032
0.81
5677
6
0.190
4.83
0.032
0.81
5678
7
0.190
4.83
0.032
0.81
5679
8
0.202
5.13
0.032
0.81
5680
10
0.228
5.79
0.032
0.81
5681
15
0.252
6.40
0.032
0.81
24 AWG (0.23 mm
2
)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
5092C
2
0.160
4.06
0.032
0.81
5093C
3
0.167
4.24
0.032
0.81
5094C
4
0.179
4.55
0.032
0.81
5096C
6
0.205
5.21
0.032
0.81
5098C
8
0.219
5.56
0.032
0.81
5100C
10
0.248
6.30
0.032
0.81
5100/15C
15
0.275
6.99
0.032
0.81
5100/20C
20
0.304
7.72
0.032
0.81
5100/25C
25
0.336
8.53
0.032
0.81
5100/30C
30
0.354
8.99
0.032
0.81
5100/40C
40
0.394
10.01
0.032
0.81
5100/50C
50
0.433
11.00
0.032
0.81
5100/60C
60
0.468
11.89
0.032
0.81
5100/70C
70
0.505
12.83
0.032
0.81