beautypg.com

Xtra-guard® 4 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 58

background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

86

Cable > Xtra-Guard > Xtra-Guard 4 > Multiconductor > Supra-Shield Foil/Braid > 300 V

Xtra-Guard® 4

Advanced Temperature and Chemical Performance

300 V Supra-Shield® Foil/Braid, Multiconductor

UL AWM 20237

UL PLTC

CSA AWM I/II A/B FT1

MSHA P-07-KA070017-MSHA

NEC Class 1, Div 2 (22 &

20 AWG)

Operating Temperature

• –50°C to +125°C

Conductor Color Coding

• 24, 22 AWG: Chart E (page 520)

• 20, 18, 16 AWG: Chart D

(page 519)

• Nine jacket colors

(black standard)

• Custom colors available

Materials

• Stranded tinned copper

conductors

• TPE insulation

• TPE jacket

• Supra-Shield foil + braid shield:

Aluminum/polyester/aluminum

foil with 25% overlap min.

Tinned copper drain wire sized

the same as conductors

Tinned copper braid, 70%

coverage min.

• Nylon ripcord

Availability

Made to order

1000 ft (305 m) minimum

FIT® Tubing Recommendations

• FIT-600: highly flexible,

cross-linked elastomer

• FIT-400: temperature/chemical

resistant FEP

24 AWG (0.23 mm

2

)

Stranding: 7/32 (7 x 0.20 mm)

Insulation thickness: 0.016 (0.41 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

45112

2

0.228

5.79

0.042

1.07

45113

3

0.237

6.02

0.042

1.07

45114

4

0.252

6.40

0.042

1.07

45116

6

0.285

7.24

0.042

1.07

45118

8

0.303

7.70

0.042

1.07

45120

10

0.340

8.64

0.042

1.07

45120/15

15

0.375

9.53

0.042

1.07

45120/20

20

0.411

10.44

0.042

1.07

45120/25

25

0.452

11.48

0.042

1.07

22 AWG (0.35 mm

2

)

Stranding: 7/30 (7 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

45102

2

0.246

6.25

0.045

1.14

45103

3

0.256

6.50

0.045

1.14

45104

4

0.272

6.91

0.045

1.14

45106

6

0.309

7.85

0.045

1.14

45108

8

0.329

8.36

0.045

1.14

45110

10

0.370

9.40

0.045

1.14

45110/15

15

0.428

10.87

0.055

1.40

45110/20

20

0.469

11.91

0.055

1.40

45110/25

25

0.514

13.06

0.055

1.40

20 AWG (0.56 mm

2

)

Stranding: 7/28 (7 x 0.32

mm)

Insulation thickness: 0.016 (0.41 mm)

Part No.

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

45152

2

0.262

6.65

0.045

1.14

45153

3

0.273

6.93

0.045

1.14

45154

4

0.292

7.42

0.045

1.14

45156

6

0.334

8.48

0.045

1.14

45158

8

.0356

9.04

0.045

1.14

45160

10

0.422

10.72

0.055

1.40

45160/15

15

0.465

11.81

0.055

1.40

45160/20

20

0.511

12.98

0.055

1.40

45160/25

25

0.562

14.27

0.055

1.40

* UL AWM 20237, CSA AWM I/II A/B FT1 only