Xtra-guard® 4 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual
Page 58

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
86
Cable > Xtra-Guard > Xtra-Guard 4 > Multiconductor > Supra-Shield Foil/Braid > 300 V
Xtra-Guard® 4
Advanced Temperature and Chemical Performance
300 V Supra-Shield® Foil/Braid, Multiconductor
UL AWM 20237
UL PLTC
CSA AWM I/II A/B FT1
MSHA P-07-KA070017-MSHA
NEC Class 1, Div 2 (22 &
20 AWG)
Operating Temperature
• –50°C to +125°C
Conductor Color Coding
• 24, 22 AWG: Chart E (page 520)
• 20, 18, 16 AWG: Chart D
(page 519)
• Nine jacket colors
(black standard)
• Custom colors available
Materials
• Stranded tinned copper
conductors
• TPE insulation
• TPE jacket
• Supra-Shield foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
Availability
Made to order
1000 ft (305 m) minimum
FIT® Tubing Recommendations
• FIT-600: highly flexible,
cross-linked elastomer
• FIT-400: temperature/chemical
resistant FEP
24 AWG (0.23 mm
2
)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
45112
2
0.228
5.79
0.042
1.07
45113
3
0.237
6.02
0.042
1.07
45114
4
0.252
6.40
0.042
1.07
45116
6
0.285
7.24
0.042
1.07
45118
8
0.303
7.70
0.042
1.07
45120
10
0.340
8.64
0.042
1.07
45120/15
15
0.375
9.53
0.042
1.07
45120/20
20
0.411
10.44
0.042
1.07
45120/25
25
0.452
11.48
0.042
1.07
22 AWG (0.35 mm
2
)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
45102
2
0.246
6.25
0.045
1.14
45103
3
0.256
6.50
0.045
1.14
45104
4
0.272
6.91
0.045
1.14
45106
6
0.309
7.85
0.045
1.14
45108
8
0.329
8.36
0.045
1.14
45110
10
0.370
9.40
0.045
1.14
45110/15
15
0.428
10.87
0.055
1.40
45110/20
20
0.469
11.91
0.055
1.40
45110/25
25
0.514
13.06
0.055
1.40
20 AWG (0.56 mm
2
)
Stranding: 7/28 (7 x 0.32
mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
45152
2
0.262
6.65
0.045
1.14
45153
3
0.273
6.93
0.045
1.14
45154
4
0.292
7.42
0.045
1.14
45156
6
0.334
8.48
0.045
1.14
45158
8
.0356
9.04
0.045
1.14
45160
10
0.422
10.72
0.055
1.40
45160/15
15
0.465
11.81
0.055
1.40
45160/20
20
0.511
12.98
0.055
1.40
45160/25
25
0.562
14.27
0.055
1.40
* UL AWM 20237, CSA AWM I/II A/B FT1 only