Xtra-guard® 1 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual
Page 27

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
55
22 AWG (0.35 mm
2
)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Pairs
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
5121C
1
0.196
4.98
0.032
0.81
5122C
2
0.260
6.60
0.032
0.81
5123C
3
0.273
6.93
0.032
0.81
5124C
4
0.295
7.49
0.032
0.81
5125C
5
0.319
8.10
0.032
0.81
5126C
6
0.344
8.74
0.032
0.81
5129C
9
0.396
10.06
0.032
0.81
5129/11C
11
0.424
10.77
0.032
0.81
5129/15C
15
0.475
12.07
0.032
0.81
5129/19C
19
0.507
12.88
0.032
0.81
5129/27C
27
0.649
16.48
0.053
1.35
Cable > Xtra-Guard > Xtra-Guard 1 > Multipair > Supra-Shield Foil/Braid > 300 V
Xtra-Guard® 1
High Performance
300 V Supra-Shield® Foil/Braid, Multipair
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart B
(page 516)
• 20, 18 AWG: Chart A (page 516)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 31, minimums
may apply)
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Supra-Shield foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
20 AWG (0.56 mm
2
)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Pairs
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
5292C
2
0.326
8.28
0.032
0.81
5293C
3
0.344
8.74
0.032
0.81
5296C
6
0.443
11.25
0.032
0.81
5299C
9
0.515
13.08
0.032
0.81
5299/19C
19
0.719
18.26
0.053
1.35
18 AWG (0.81 mm
2
)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Pairs
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
5132C
2
0.355
9.02
0.032
0.81
5133C
3
0.376
9.55
0.032
0.81
5136C
6
0.488
12.40
0.032
0.81
5139C
9
0.611
15.52
0.053
1.35
5139/27C
27
1.004
25.50
0.083
2.11