beautypg.com

Xtra-guard® 1 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual

Page 18

background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

46

Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 300 V

Xtra-Guard® 1

High Performance

300 V Supra-Shield® Foil/Braid, Multiconductor

UL CM

UL AWM 2464 VW-1

CSA CMG FT4

Operating Temperature

• –30°C to +80°C (AWM)

• –30°C to +105°C (CM)

Conductor Color Coding

• 28, 26, 24, 22 AWG: Chart E

(page 520)

• 20, 18, 16 AWG: Chart D

(page 519)

• Jacket Colors

• Put-ups: slate

• Bulk: nine colors available

(page 31, minimums

may apply)

Materials

• Stranded tinned copper

conductors

• Premium PVC insulation

• Supra-Shield foil + braid shield:

Aluminum/polyester/aluminum

foil with 25% overlap min.

Tinned copper drain wire sized

the same as conductors

Tinned copper braid, 70%

coverage min.

• Nylon ripcord

• Premium PVC jacket

• UV resistant

Availability

100 ft (30.5 m)

500 ft (152 m)

1000 ft (305 m)

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-221: General-purpose,

cross-linked polyolefin (indoor)

• FIT-321: Medium-wall,

adhesive-lined, cross-linked

polyolefin (outdoor)

18 AWG (0.81 mm

2

)

Stranding: 16/30 (16 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5162/1C*

2

0.254

6.45

0.032

0.81

5162C

2

0.254

6.45

0.032

0.81

5163/1C*

3

0.266

6.76

0.032

0.81

5163C

3

0.266

6.76

0.032

0.81

5164C

4

0.287

7.29

0.032

0.81

5166C

6

0.335

8.51

0.032

0.81

5168C

8

0.360

9.14

0.032

0.81

5170C

10

0.412

10.46

0.032

0.81

5170/15C

15

0.461

11.71

0.032

0.81

5170/20C

20

0.512

13.00

0.032

0.81

5170/25C

25

0.612

15.54

0.053

1.35

5170/30C

30

0.651

16.54

0.053

1.35

5170/40C

40

0.722

18.34

0.053

1.35

*Conductors color-coded per international standards: brown, blue, green/yellow.

16 AWG (1.23 mm

2

)

Stranding: 19/0.0117 (19 x 0.29 mm)

Insulation thickness: 0.016 (0.41 mm)

Part Number

Conductors

Nominal Diameter

Jacket Thickness

Inch

mm

Inch

mm

5172/1C*

2

0.278

7.06

0.032

0.81

5172C

2

0.278

7.06

0.032

0.81

5173/1C*

3

0.292

7.42

0.032

0.81

5173C

3

0.292

7.42

0.032

0.81

5174C

4

0.316

8.03

0.032

0.81

5176C

6

0.371

9.42

0.032

0.81

5178C

8

0.400

10.16

0.032

0.81

5180C

10

0.460

11.68

0.032

0.81

5180/15C

15

0.516

13.11

0.032

0.81

5180/20C

20

0.617

15.67

0.053

1.35

5180/25C

25

0.690

17.53

0.053

1.35

*Conductors color-coded per international standards: brown, blue, green/yellow.