Xtra-guard® 1 – Northern Connectors Alpha Wire XTRA-GUARD Performance Cable User Manual
Page 18
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
46
Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 300 V
Xtra-Guard® 1
High Performance
300 V Supra-Shield® Foil/Braid, Multiconductor
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart E
(page 520)
• 20, 18, 16 AWG: Chart D
(page 519)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 31, minimums
may apply)
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Supra-Shield foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
18 AWG (0.81 mm
2
)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
5162/1C*
2
0.254
6.45
0.032
0.81
5162C
2
0.254
6.45
0.032
0.81
5163/1C*
3
0.266
6.76
0.032
0.81
5163C
3
0.266
6.76
0.032
0.81
5164C
4
0.287
7.29
0.032
0.81
5166C
6
0.335
8.51
0.032
0.81
5168C
8
0.360
9.14
0.032
0.81
5170C
10
0.412
10.46
0.032
0.81
5170/15C
15
0.461
11.71
0.032
0.81
5170/20C
20
0.512
13.00
0.032
0.81
5170/25C
25
0.612
15.54
0.053
1.35
5170/30C
30
0.651
16.54
0.053
1.35
5170/40C
40
0.722
18.34
0.053
1.35
*Conductors color-coded per international standards: brown, blue, green/yellow.
16 AWG (1.23 mm
2
)
Stranding: 19/0.0117 (19 x 0.29 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
Nominal Diameter
Jacket Thickness
Inch
mm
Inch
mm
5172/1C*
2
0.278
7.06
0.032
0.81
5172C
2
0.278
7.06
0.032
0.81
5173/1C*
3
0.292
7.42
0.032
0.81
5173C
3
0.292
7.42
0.032
0.81
5174C
4
0.316
8.03
0.032
0.81
5176C
6
0.371
9.42
0.032
0.81
5178C
8
0.400
10.16
0.032
0.81
5180C
10
0.460
11.68
0.032
0.81
5180/15C
15
0.516
13.11
0.032
0.81
5180/20C
20
0.617
15.67
0.053
1.35
5180/25C
25
0.690
17.53
0.053
1.35
*Conductors color-coded per international standards: brown, blue, green/yellow.