Page 99: C13910 | i&m1 system designation, C13911 | i&m1 installation site, C13912 | i&m2 installation date, C13913 | i&m3 additional information, C13910, C13911, C13912

background image

Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 9.0 EN · 12/2013 · TD17

99

14

Parameter reference

14.2

Parameters of the communication module for slot MXI1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13900

C13901

C13902

C13910

C13911

C13912

C13913

Parameter | Name:

C13900 | Firmware Product Type

Data type: VISIBLE_STRING

Index: 10675 = 0x29B3

The code contains a string with a length of 8 characters. The identification code "E94AFCER" is displayed.

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13901 | Firmware Compilation Date

Data type: VISIBLE_STRING

Index: 10674 = 0x29B2

The code contains a string with a length of 20 characters. The software creation date ("MMM DD YYYY") and time

("hh:mm:ss") are displayed (e.g. "Mar 21 2005 12:31:21").

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13902 | Firmware Version

Data type: VISIBLE_STRING

Index: 10673 = 0x29B1

The code contains a string with a length of 8 characters. The identification code is displayed (e.g. "01.10.09").

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13910 | I&M1 system designation

Data type: VISIBLE_STRING

Index: 10665 = 0x29A9

Input/output of the I&M1 plant identification code

The Lenze setting shows an empty string.

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13911 | I&M1 installation site

Data type: VISIBLE_STRING

Index: 10664 = 0x29A8

Input/output of the I&M1 location identification code

The Lenze setting shows an empty string.

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13912 | I&M2 installation date

Data type: VISIBLE_STRING

Index: 10663 = 0x29A7

Input/output of the I&M2 date of installation

The Lenze setting shows an empty string.

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13913 | I&M3 additional information

Data type: VISIBLE_STRING

Index: 10662 = 0x29A6

Input/output if the I&M3 additional information

The Lenze setting shows an empty string.

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT