C13002 | gateway address, C13003 | mac id, C13010 | active ip address – Lenze E94AYCER User Manual
Page 92: C13011 | active subnetwork mask, C13010, C13011, C13002, Mask) and, C13010/1, C13011/1

14
Parameter reference
14.2
Parameters of the communication module for slot MXI1
92
Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 9.0 EN · 12/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13002
C13003
C13010
C13011
Parameter | Name:
C13002 | Gateway address
Data type: UNSIGNED_32
Index: 11573 = 0x2D35
Setting of the gateway address
Setting the IP configuration ( 37)
Setting range
(min. value | unit | max. value)
Lenze setting
0
4294967295 0
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13003 | MAC ID
Data type: OCTET_STRING
Index: 11572 = 0x2D34
Display of the MAC-ID
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13010 | Active IP address
Data type: UNSIGNED_8
Index: 11565 = 0x2D2D
Display of the active IP address
The active IP address may differ from the contents of code
, depending on whether the station name was
changed via the fieldbus or the parameter(
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C13010/1
Active IP address.1
C13010/2
Active IP address.2
C13010/3
Active IP address.3
C13010/4
Active IP address.4
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13011 | Active subnetwork mask
Data type: UNSIGNED_8
Index: 11564 = 0x2D2C
Display of the active subnetwork mask
The active subnet mask may differ from the contents of code
, depending on whether the station name was
changed via the fieldbus or the parameter (
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C13011/1
Active subnetwork mask.1
C13011/2
Active subnetwork mask.2
C13011/3
Active subnetwork mask.3
C13011/4
Active subnetwork mask.4
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT