C13864 | active station name, C13865 | display: last safety prm data, C13864 – Lenze E94AYCER User Manual
Page 95: 14 parameter reference

Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 9.0 EN · 12/2013 · TD17
95
14
Parameter reference
14.2
Parameters of the communication module for slot MXI1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13864
C13865
Parameter | Name:
C13864 | Active station name
Data type: VISIBLE_STRING
Index: 10711 = 0x29D7
Display of the active station name used by the drive.
The active station name may differ from the contents of code
, depending on whether the station name was
changed via the fieldbus or the parameter (
Setting the station name ( 35)
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13865 | Display: Last safety PRM data
Data type: OCTET_STRING
Index: 10710 = 0x29D6
Display of the F_parameters sent last.
• These data are only valid if PROFIsafe is activated.
• The coding of the F_parameters is described in the PROFIsafe profile V2.0.
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Bytes
Information
0
Slot
1
2
Subslot
3
4
Recldx
5
6
Accepted length
...
9
10
F_parameter
...
24