C13000 | ip address, C13001 | subnetwork mask, C13000 – Lenze E94AYCER User Manual
Page 91: Ess), C13001, 14 parameter reference
Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 9.0 EN · 12/2013 · TD17
91
14
Parameter reference
14.2
Parameters of the communication module for slot MXI1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.2
Parameters of the communication module for slot MXI1
This chapter lists the parameters of the E94AYCER communication module (PROFINET) for slot MXI2
of the Servo Drive 9400 in numerically ascending order.
C13000
C13001
Note!
PROFINET command "Reset to Factory Defaults"
If the "Reset to factory defaults" PROFINET command is executed by an IO supervisor or
an IO controller, only the following PROFINET-related parameters of the communication
module will be reset to standard values:
•
| IP address
•
| Subnetwork mask
•
| Gateway address
•
| Active IP address
•
| Active subnetwork mask
•
| Active gateway address
•
| Active station name
•
| Station name
•
| I&M1 system designation
•
| I&M1 installation site
•
| I&M2 installation date
•
| I&M3 additional information
•
| I&M4 signature code
Parameter | Name:
C13000 | IP address
Data type: UNSIGNED_32
Index: 11575 = 0x2D37
Setting of the IP address
Setting the IP configuration ( 37)
Setting range
(min. value | unit | max. value)
Lenze setting
0
4294967295 0
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13001 | Subnetwork mask
Data type: UNSIGNED_32
Index: 11574 = 0x2D36
Setting of the subnet mask
Setting the IP configuration ( 37)
Setting range
(min. value | unit | max. value)
Lenze setting
0
4294967295 0
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT